![Texmate DI-50EB51 Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/texmate/di-50eb51/di-50eb51_manual_1097557058.webp)
Texmate, Inc. Tel. (760) 598-9899
•
www.texmate.com
Page 58
6/23/04 DI-50B51 320 Series (NZ306)
I
-
S
e
r
i
e
s
I
npu
t
Sig
n
al
C
o
nd
i
ti
o
n
i
n
g
M
o
du
l
e
s
c
o
n
ti
nu
e
d
I
-
S
e
r
i
e
s
I
npu
t
Sig
n
al
C
o
nd
i
ti
o
n
i
n
g
M
o
du
l
e
s
c
o
n
ti
nu
e
d
ITP1:
Triple 4 to 20mA
+ 24V Exc
CH3
CH1
CH2
TRIPLE 4 to 20mA
TIGER
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
4 to 20mA
4 to 20mA
4 to 20mA
168D
ITT1
: Triple Thermocouple (J/
K
/R/S/T/B/N)
TIGER
111G
+
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
CH1
+
–
GND
24V EXC
CH3
+
–
CH2
+
–
ITD1:
Triple DC Volts,
2V DC
ITD2:
Triple DC mV,
50mV DC
+ 24V Exc
TRIPLE DC VOLTS
+ Volts or mV (CH1)
+ Volts or mV (CH2)
+ Volts or mV (CH3)
TIGER
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
168D
Pt-100
Ω
RTD
4 wire
4 wire
3 wire
3 wire
LEAD
COMP
LIN
RTD
IT03:
RTD, 100
Ω
Pt. 2/
3
/4-wire (-200 to 800
°
C)
IT04:
RTD, 100
Ω
Pt. 2/
3
/4-wire (-200 to 1470
°
F)
IT05:
RTD, 100
Ω
Pt. 2/
3
/4-wire (-199.9 to 199.9
°
F)
IT14:
RTD, 100
Ω
Pt. 2/
3
/4-wire (-199.9 to 199.9
°
C)
Excitation is 1mA
Up to 50
Ω
resistance in each
lead can be compensated
Typical accuracy is
±
(0.3% + 1 digit)
LINEARISATION IS ANALOG
LEOPARD
LYNX
TIGER
IT02
187C
IT02
: RTD, 100
Ω
Pt. 2.3.4-wire
IT12
: RTD, 120
Ω
Nickel 2/
3
/4-wire
IT13
: RTD, 10
Ω
Copper 2/
3
/4-wire
IM-RTD
Pt 100
Ω
, 120
Ω
Nickel
or 10
Ω
Copper RTD
TIGER
128A
IT01
: Thermocouple (J/
K
/R/S/T/B/N)
TIGER
111G
+
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
CH1
+
–
GND
Not Used
Not Used
Not Used
Not Used
24V EXC
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
PIN 9
PIN 10
PIN 11
PIN 12
PIN 13
PIN 14
PIN 15
PIN 16
360A
IST1:
Smart 6 Inputs- 3 RTDs, 2 Proc. & 1 Dig. Input. 50 Hz
IST2:
Smart 6 Inputs- 3 RTDs, 2 Proc. & 1 Dig. Input. 60 Hz
TIGER
PROCESS 2
(0 - 10 V / 0 - 20 mA)
PROCESS 1
(0 - 10 V / 0 - 20 mA)
X 3 RTD 100
Ω
COUNTER
(CH 1)
EXC
EXC
EXC - RTN
EXC - RTN
EXC - RTN
NOT USED
ITTA
: Triple Input- T/C (J/
K
/R/S/T/B/N),
4 to 20mA and 50mV DC
ITTB
: Triple Input- T/C (J/
K
/R/S/T/B/N),
4 to 20mA and 2VDC
TIGER
111I
+
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
CH1
+
–
GND
24V EXC
CH3
mVDC or VDC
CH2
+
–
+
–
All three RTDs
must
be connected for the meter to work.
ITTC:
Triple RTD Platinum 100
Ω
RTD
4 Wire Connection
TIGER
CH2
100
Ω
Pt RTD
CH1
CH1
CH2
CH3
CH4
2 Wire
4 Wire
100
Ω
Pt RTD
CH3
100
Ω
Pt RTD
236C
ITT9
: Triple Input- T/C (J/
K
/R/S/T/B/N),
DCV and 50mV DC
TIGER
111I
+
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
CH1
+
–
GND
24V EXC
CH3
mVDC
CH2
DCV
+
–
+
–
ITT8
: Triple Input- T/C (J/
K
/R/S/T/B/N),
4 to 20mA and 4 to 20mA
TIGER
111I
+
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
CH1
+
–
GND
24V EXC
CH3
CH2
+
–
+
–
ITT6
: Triple Input- T/C (J/
K
/R/S/T/B/N),
50mV DC and 50mV DC
ITT7
: Triple Input- T/C (J/
K
/R/S/T/B/N),
2VDC and 2VDC
TIGER
111I
+
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
CH1
+
–
GND
24V EXC
CH2
mVDC or VDC
CH3
mVDC or VDC
+
–
+
–
ITT4
: Triple Input- T/C, T/C (J/
K
/R/S/T/B/N)
and 4 to 20mA
TIGER
111I
+
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
CH1
+
–
GND
24V EXC
CH2
+
–
CH3
ITT3
: Triple Input- T/C, T/C (J/
K
/R/S/T/B/N)
and 2VDC Input
ITT5
: Triple Input- T/C, T/C (J/
K
/R/S/T/B/N)
and 50mV DC
TIGER
111I
+
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
CH1
+
–
GND
24V EXC
CH2
+
–
CH3
VDC or mVDC
+
–
ITTF
: Triple Input - Thermocouple / 4-20mA / Frequency
ITTG
: Triple Input - Thermocouple / V / Frequency
TIGER
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
+24 V EXC
+
+
FREQ/CNTR INPUT (CH2)
GND (AC mV)
DC CURRENT/VOLTAGE
(CH3)
TC (CH1)
GND (TTL, PNP, NPN)
EXC OUT
m
V
O
N
F
ilte
r
O
F
F
C
u
s
to
m
2
0
m
A
1
0
V
2
V
V
C
tr
F
q
T
T
L
N
P
N
P
N
P
307B
ITTE
: Triple Input- RTD / RTD / FREQ
TIGER
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
PIN 9
PIN 10
PIN 11
+24 V EXC
GND (AC mV)
FREQ/CNTR INPUT (CH2)
GND (TTL, PNP, NPN)
N/C
PT 100
Ω
RTD (CH1)
PT 100
Ω
RTD (CH3)
FREQ
CNTR
N
P
N
P
N
P
O
F
F
O
N
FILTER
T
T
L
M
V
OC
342A
All three RTDs
must
be connected for the meter to work.
ITT2:
Triple RTD Platinum 100
Ω
RTD
2 Wire Connection
TIGER
CH2
100
Ω
Pt RTD
CH1
CH1
CH2
CH3
CH4
2 Wire
4 Wire
100
Ω
Pt RTD
CH3
100
Ω
Pt RTD
236C
+
30
0 V
70
0 V
Current Input
Voltage Input
PIN 3
PIN 4
1
2
SINGLE PHASE POWER
IWO1
: Single Phase Power,
300V
/1A
IWO2
: Single Phase Power,
300V
/5A
IWO4
: Single Phase Power,
700V
/1A
IWO5
: Single Phase Power,
700V
/5A
TIGER
1A / 5A
Secondary
CT
1 A
S
H
U
N
T
300V / 700V
Max
235H
IW03
: DC-Watts,
10V/50mV DC
TIGER
124C
381B
IST3:
Smart Quad Thermocouple. 50 Hz
IST4:
Smart Quad Thermocouple. 60 Hz
TIGER
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
TC1 +
TC1
–
TC2 +
TC2
–
TC3 +
TC3
–
TC4 +
TC4
–
TC4
TC3
TC2
TC1
382C
IST5:
Smart Dual RTD with 0.01
˚
Res. 50 Hz
IST6:
Smart Dual RTD with 0.01
˚
Res. 60 Hz
TIGER
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
+ EXC 1
—
EXC 1
+ EXC 2
—
EXC 2
+ SENSE 1
—
SENSE 1
+ SENSE 2
4-WIRE
RTD 1
4-WIRE
RTD 2
—
SENSE 2