![Texmate DI-50EB51 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/texmate/di-50eb51/di-50eb51_manual_1097557023.webp)
Page 23
6/23/04 DI-50B51 320 Series (NZ306)
Texmate, Inc. Tel. (760) 598-9899
•
www.texmate.com
From Step 6
Step 4
Step 5
Step 3
Step 1
Step 2
Operational Display
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
Press
at same
time
Press
at same
time
Enter Brightness Mode
80
100
90
70
60
50
40
30
20
SP
SP
6
5
4
3
2
1
10
0
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
Press
2
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
Press
1
80
100
90
70
60
50
40
30
20
SP
SP
6
5
4
3
2
1
10
0
Press
1
Step 7
Step 8
Step 9
Step 10
Step 11
Exit Code 1.
Return to
Operational Display
Operational Display
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
Press
1
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
Press
1
Press
at same
time
Press
at same
time
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
80
100
90
70
60
50
40
30
20
10
0
SP
SP
6
5
4
3
2
1
To Step 7
Pass Brightness Mode and
enter Calibration Mode
Select the No Function
Calibration Mode [000]
Save Calibration Mode [000]
setting and enter Code 1
Enter Cal Mode [111]
For 2-point calibration
of CH1
5.2. Apply the LOW
input signal
5.1. Adjust
display to
desired reading for
zero input
7.2. Apply the
HIGH
input signal
7.1. Adjust display
to desired reading
for span input
Step 6
Set reading for zero load into
meter and enter Span Mode
Save zero and span settings
and re-enter Calibration Mode
LOW
Signal
HIGH
Signal
Set Calibration Mode to [111]:
1st Digit = 1
Selects calibration procedures
2nd Digit = 1
Selects 2-point calibration
3rd Digit = 1
Selects CH1 for calibration
Example
Example
TWO-POINT
CALIBRATION
OR
OR
OR
OR
LOW
Signal
HIGH
Signal
The low input source is applied to
the meter when setting the zero
value.
The high input source is applied
to the meter when setting the
span value.
Two-point Calibration
Two-point calibration is the most commonly used method of cal-
ibrating Tiger 320 Series meters when a low and high input
source is available.
Example Calibration Procedure
Calibrate channel 1 (CH1) using the two-point calibration
method. The calibration mode display is set to
[111]
.
ST
ST
AR
AR
T HERE
T HERE
[
C
A
L
]
-
C
ali
b
r
ati
o
n
M
o
d
e
s
f
o
r
I
npu
t
a
nd
O
u
t
pu
t
c
o
n
ti
nu
e
d
[
C
A
L
]
-
C
ali
b
r
ati
o
n
M
o
d
e
s
f
o
r
I
npu
t
a
nd
O
u
t
pu
t
c
o
n
ti
nu
e
d