TSP Edge User’s Manual
40-400-00065, Rev. E
11
Optional Software Modules
•
TSP-PRI: Adds T1 or E1 Primary Rate ISDN (you select T1 or E1 upon
installation) NOTE: For older TSP-BASE units, only T1 PRI is available.
•
TSP-2PRI: Extends TSP-PRI module to include both T1 and E1 Primary Rate
ISDN. NOTE: For TSP Edge units only.
•
TSP-ATS, Advanced Test Scripting software module. NOTE: For TSP Edge units
only.
If any of the items you ordered are missing or damaged, please contact Teltone
customer service.
Caution:
The Edge modules are (electro-static discharge) sensitive devices and
are shipped in static shield packaging. Proper precautions are needed to avoid
damaging them when handled. Teltone Corporation requires any returned
modules to be properly packaged in static shield packaging.
Installing Hardware Modules
Before applying power to the Edge, ensure that the telephony interface modules are
installed per the following information and Table 1. Ensure the modules are securely
seated and the thumb-screws are tightened.
Note:
Slot count is 1-4 from left to right when looking at the back of the Edge.
1.
If using a T1/E1 module, install it in slot 4.
a. Two T1/E1 modules may be used ONLY if they are both Single T1/E1
modules and no other modules are installed. Install the Single T1/E1
modules in slots 3 and 4.
2.
When installing POTS modules (both FXO and FXS types), install the first
module in slot 3 and work to the left.
a. If installing both FXO and FXS modules, place the FXS modules to the
left of the FXO modules.
b. If installing both 4 and 8 Port POTS FXS modules, place the 4 Port
module to the left of the 8 Port module.
c. When using a 4-Port POTS module, at most only one other module may
be installed.
Содержание TSP Edge
Страница 1: ...TSP Edge User s Manual 40 400 00065 Rev E ...