TSP Edge User’s Manual
40-400-00065, Rev. E
23
Unit Configuration Summary
1. Select New on the Units menu and name the unit.
The Unit dialog box is displayed.
2. In the Unit dialog box, configure the Serial Connection setting on the
General tab by selecting the appropriate Comm Port.
3. Click the Query Card Types button at the bottom of the Unit dialog box.
The information on the Slot tabs in the Unit dialog box now reflects the physical
modules in the Edge.
4. Click OK in the Unit dialog box.
5. If a message stating that "Newer code is available" is displayed, click
No
and follow the instructions in “Newer Software Versions” on page 20.
6. Re-open the Unit dialog box for your unit.
7. If network control is needed, assign a valid IP address to the unit, and
select Network connection.
Module Configuration
Slot Tabs
Once the card types and the connection to the Edge are defined, there are many
different options to configure for each card type. Choose each Slot tab that has a
module installed and configure it according to the following subsections.
Single T1/E1 and Dual T1/E1 Card Types
For T1/E1 modules, the Card Mode field is displayed to the right of the Card Type
field. T1 is displayed by default. Clicking the arrow displays the E1, T1-PRI and E1-
PRI options.
Note:
T1-PRI and E1-PRI are available when optional software module(s) are
purchased. For more information, see “Primary Rate ISDN Software Modules
(TSP-PRI and TSP-2PRI)” on page 87.
When using two single T1/E1 modules, both modules have to be configured for the
same card mode and PCM encoding/companding. Therefore, the selections for Card
Mode and mu-law or a-law are disabled for one of the slots.