Call Timings and Process Flowcharts
Call Timings
Timings are used to control the intervals of all the different parts of the call process while the
TSP Edge is originating or terminating calls. The default times should be appropriate for
most testing.
There are three sections on the Timings screen:
Timings in the
Originating Calls
section are used when the Edge is generating calls to
the equipment under test.
Timings in the
Terminating Calls
section are used when the Edge is receiving
incoming calls from the equipment under test.
Timings in the
All Calls
section apply to both incoming and outgoing calls.
Not all timings are used by each protocol or by each call type. The Timings tab on the
Templates screen in the Edge configuration software only displays the timings that are
appropriate to the selected protocol. For details on how the timings are applied, see “Call
Process Flowcharts” on page 128.
The following describes each timing parameter.
Originating Calls
Wait For Seize
Acknowledge
Time Edge waits to receive a seize acknowledge after
sending a seizure.
Wait For Delay Dial Start
Time Edge waits to receive the beginning of a Delay Dial
signal after sending a seizure.
Wait For Wink Start
Time Edge waits to receive the beginning of a Wink signal
after sending a seizure.
Wait For Delay Dial End
Time Edge waits to receive the end of a Delay Dial signal
after receiving the beginning of the Delay Dial signal.
Wait For Wink End
Time Edge waits to receive the end of a Wink signal after
receiving the beginning of the Wink signal.
Delay Before Dial
The delay before the Edge starts transmitting digits for
each call made by the Edge.
Wait for Answer
The time the Edge waits before abandoning a call if there is
no answer.