TSP Edge User’s Manual
40-400-00065, Rev. E
56
A channel can be placed in a certain signaling state by clicking the appropriate button
in the channel’s box. Ringing is forced by clicking the
button. Off-hook is forced
by clicking the
button. On-hook is forced by clicking the
button. The Normal
button puts the channel back to normal operation. In addition,
all
channels can be
placed in a certain state by clicking the All Normal, All Ring, All Off-Hook, or All
On-Hook buttons.
To view the signaling bits states for T1/E1 channels, click the Monitor button for the
channel. For ESF framing and E1, the ABCD bit states are indicated. For D4 framing,
the bit states are indicated in ABAB format. Only one channel can be monitored at a
time.
To exit Diagnostics, select Exit on the Diagnostics menu.
Trace
The step by step call progress of a channel can be displayed with the Trace screen
(see Figure 39). This feature is helpful for troubleshooting problems on calls.
Figure 39. Trace Screen
Select Trace on the Tools menu. Choose the channel to be monitored from the
Channel list. The information will scroll as calls are made on the channel.
Содержание TSP Edge