TSP Edge User’s Manual
40-400-00065, Rev. E
39
buttons become available at this point and the bit state Outbound (end initiating call)
and Inbound (end receiving the call) fields can be edited. A 1 or 0 can be entered into
these fields since signaling is done in a binary form. An X is used for a Receive Bit
when that signaling bit is not used.
Information on the bit states for the equipment being tested by the Edge should be
obtained from the manual, vendor or technical support of that product.
Notes:
For T1, when using D4 framing, the bit fields are in ABAB format and
the C and D bits must match the A and B bit fields. This is because D4 does not
employ C and D bits and will cause signaling problems.
For E1, the C and D bits must be set for 0 and 1 respectively. Otherwise,
synchronization problems will occur.
Set as Default for (Channel Protocol) Button
The Set as Default for (channel protocol) button allows the user to set a predefined
protocol other than the factory default to be used when a Channel Protocol is chosen
on the Type tab. This allows the assignment of the channel protocol without having to
go to the Signaling tab each time.
Undo Changes Button
The Undo Changes button sets the signaling back to the predefined protocol listed
before checking the User Define button. The same thing can be done by clicking the
down arrow for the predefined protocols and choosing one.
Save As Button
The Save As… button is used to assign a name to the signaling protocol states
defined in the User Define section. Once saved, the name will be available in the
predefined protocols list when clicking the down arrow.
Template Configuration Summary
1. Create templates to configure the channel protocols based on the modules
being used (i.e., Analog Loop Start templates for POTS, and T1 Wink
Start template for T1/E1 modules). A template is associated with the
channels to be tested when a control set is created. To create a template,
select New on the Templates menu.
2. Click the Channel Protocol arrow for a list of available protocols. For
more information about the protocols, see “Type Tab” on page 34. Analog
Loop Start templates are only used for the POTS modules. Start by using
the defaults for all the fields on the template.