TSP Edge User’s Manual
40-400-00065, Rev. E
33
Note:
The error message “Installed card types do not match defined card
types” indicates a configuration mismatch between the physical modules in
the Edge and card types selected on the Unit screen. If this message occurs,
click OK, and open the Unit screen, and select the Edge to edit. Verify and
correct the settings. To avoid this error, it is recommended that you
automatically configure the Edge by using the Query Card Types button.
Module Configuration Summary
1. If using a T1/E1 module, select the Slot tab that corresponds to the
module’s location and select the appropriate card mode from the Card
Mode list. The T1 or E1 tab is used to set the parameters according to the
equipment being tested.
Note:
T1-PRI and E1-PRI are available when optional software
module(s) are purchased. For more information, see “Primary Rate
ISDN Software Modules (TSP-PRI and TSP-2PRI)” on page 87.
2. If using T1-PRI or E1-PRI mode, a PRI tab appears. Set the appropriate
Switch Type and Simulation, which is the end the Edge will be simulating.
3. Configure the Channels tab for all the installed modules. Each channel can
be assigned a Phone Number (T1, E1 and POTS), Transmit Digits (i.e.,
ANI and DNIS for T1 and E1), and Audio Message (the network
connection must be established). For T1-PRI and E1-PRI, Subaddress,
Called Number and Calling Number features are also available. For more
information, see “Channels Tab” on page 29.
The Channel Configuration Wizard button can be used to assign values to
all the channels at once. For more information, see “Channel
Configuration Wizard” on page 32.
4. Click OK to exit the Unit screen.
The configuration information is sent to the Edge.
Templates
Templates are used to define details of the channel protocols to be used for call
simulation. The basic protocol is set on the Type tab, timings for that protocol are set
on the Timings tab, and the signaling bit patterns used for the protocol are set on the
Signaling tab.
Select New on the Templates menu. A screen requesting to "Enter New Template
Name" is displayed. It is recommended that the template name reflect the protocol
being used. This makes it easier to distinguish what the protocol of the Template is on
the Control Set(s). After entering the template name, it is displayed in the Template
Содержание TSP Edge