TSP Edge User’s Manual
40-400-00065, Rev. E
128
Call Process Flowcharts
Analog Loop Start FXO
Analog Loop Start FXO - Call Terminate
0
Ringing From equipment under test.
Delay Before Answer
timer starts.
1
Delay Before answer
timer expires
Edge answers.
Call Duration
timer starts.
Delay before Message
1
timer starts.
2
Delay before message
timer expires.
Edge starts playing audio message.
3
Edge detects COD from equipment under test.
Disconnect to start of new call
timer starts. Note: If
Call Duration
timer
expires before detecting COD from the equipment under test, the Edge
will disconnect first.
4
Disconnect to start of new call
timer expires.
Edge ready to receive next call.
1
If no Audio Message is programmed for the channel, proceed directly to step 3.
Call
Disconnect
Call
Setup
Call Connected
Delay Before
Message
TSP Plays
Audio
Message
Delay Before
Answer
Disconnect
To Start Of
New Call
0
1
2
3
4