5.2.6 Parallel Port Special Functions
In 1:1 Redundant Mode, each SSPA chassis will change some of its parallel I/O
functions to alternative functions. See
Table 5-3
for details.
Pin #
Function / Description
1
Closed on Power Supply Fault Form C relay NC
2
Open on Power Supply Fault Form C relay NO
20
Power Supply Fault Common
21
1. Standalone mode. Closed on Auxiliary Fault
2. 1:1 Redundancy Mode. Closed on Automatic switchover mode. Form C relay NC
22
1. Standalone Mode. Open on Auxiliary Fault
2. 1:1 Redundancy Mode. Closed on Manual switchover mode. Form C relay NO
3
Auxiliary Fault\Auto-Manual Common
4
Open on Mute. Form C Relay NC
5
Closed on Mute. Form C Relay NO
23
Mute Status Common
24
Closed on BUC Fault. Form C Relay NC
25
Open on BUC Fault. Form C Relay NO
6
BUC Fault Common
7
Closed on High Temperature Fault. Form C Relay NC
8
Open on High Temperature Fault. Form C Relay NO
26
High Temperature Fault Common
27
1. Standalone mode. Closed on Regulator Low Voltage Fault
2. 1:1 Redundancy Mode. Closed on HPA Standby. Form C relay NC
1. Standalone Mode. Open on Regulator Low Voltage Fault.
2. 1:1 Redundancy Mode. Closed on HPA Online Mode. Form C relay NO
9
Regulator Low Voltage Fault\Standby-Online Common
10
Closed on DC Current Low Fault. Form C Relay NC
11
Open on DC Current Low Fault. Form C Relay NO
29
DC Current Low Fault Common
30
Closed on Low Forward RF Fault. Form C Relay NC
31
Open on Low Forward RF Form C Relay NO
12
Low Forward RF Fault Common
16
Auto/Manual toggle input. 50mS Closure to isolated ground to activate
17
Mute/Unmute toggle input. 50mS Closure to isolated ground to activate
18
Auxiliary Fault & Auxiliary Mute Input (See
Section 2.1.2.7.1
). 50 ms min.
35
HPA Standby input. 50mS Closure to isolated ground to activate
36
Local/Remote toggle. 50mS Closure to isolated ground to activate
37
Fault clear. 50mS Closure to isolated ground to activate
19
Isolated Signal Ground
15
+5V Pull Up. 5mA Maximum output current
28
13, 32
+28V Auxiliary Power 1A
14, 33
Chassis Ground
Table 5-3: Parallel Connector, Highlighting 1:1 Functions