6 RU SSPA Chassis Operations Manual
202058 REV AA
71
5. Click the “Upload” button. A warning message will appear; click the “OK” but-
ton (See
Figure 3-9
).
6. The upload process will begin and the form will be informing about loading
process (See
Figure 3-10
). Do not interrupt this process and wait until its
completion with positive or negative result. The process may take up to 15
minutes. When completed, the form will notify about end of process. See
Figure 3-11
.
7. During the upgrade process, the HPA remains fully functional. The new firm-
ware will stay dormant until the next reboot of the HPA control card. Reboot
the controller card by selecting the relevant front panel menu or by turning
off AC power to the HPA. Browse to the front panel menu firmware infor-
mation page and verify the installed version.
8. If the load process was interrupted, for any reason, the HPA may not operate
properly after a reboot. It is still possible to recover from the problem by ap-
plying firmware upload over USB port. See
Section 3.1.3.4
for details.
Figure 3-9: Proceed With Upgrade Prompt
Figure 3-10: Upload Process Message
Figure 3-11: Upload Completed Message