6 RU SSPA Chassis Operations Manual
202058 REV AA
65
3.0.7 Fan Fault
In the case of a fan fault, follow the tips below. A fan fault is not a Summary fault.
•
Inspect the fans.
•
The user should check the booster board voltages on the front panel dis-
play. This can be found under the system information portion of the main
menu. The voltage should read approximately 28VDC for each of the
fans in the SSPA.
•
If necessary, replace the fan (See
Section 3.1.4
).
3.1 Modular SSPA Architecture
The Paradise Datacom SSPA Chassis consists of a modular design, which allows for
quick and easy maintenance and replacement in the event of a catastrophic failure of
one of the SSPA components.
3.1.1 SSPA Module Removal
The Rack Mount 6RU SSPA Chassis houses two SSPA modules beneath the top cov-
er plate and two SSPA modules accessible from the base plate. The cover plate and
base plate are each held in place with 16 6-32 x 1/4” flat-head screws. Remove power
to the Rack Mount SSPA before removing these.
Figure 3-2: SSPA Module Arrangements; clockwise from upper left: Modules 1 &
2 of a C-Band unit (top view); Modules 1 & 2 of a Ku-Band unit (top view);
Modules 2 & 3 of a Ku-Band unit (side view); Modules 2 & 3 of a C-Band unit
Solid State Power Amplifier
Ku-Band
Solid S
tat
e P
ow
er A
mpl
ifie
r
C-BA
ND
Содержание 6 RU Chassis
Страница 110: ...110 202058 REV AA 6 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 156: ...156 202058 REV AA 6 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 172: ...172 202058 REV AA 6 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK...