6 RU SSPA Chassis Operations Manual
Table 9-13: SNMP Detailed Conditions
conditionIndex/
conditionValue
condi onTextValue
Value
OID
Descrip on
1/INTEGER SummaryFault'NoFault=0,Fault=1
1.3.6.1.4.1.20712.2.1.3.1.2.1 Summary
fault
state
2/INTEGER
PowerSupplyFault'NoFault=0,Fault=1
1.3.6.1.4.1.20712.2.1.3.1.2.2
Power supply fault state
3/INTEGER HighTemperatureFault'NoFault=0,Fault=1 1.3.6.1.4.1.20712.2.1.3.1.2.3
High Temperature fault
state
4/INTEGER
LowRegulatorVoltageFault'NoFault=0,
Fault=1
1.3.6.1.4.1.20712.2.1.3.1.2.4
Low Regulator voltage
state
5/INTEGER LowDCCurrentFault'NoFault=0,Fault=1 1.3.6.1.4.1.20712.2.1.3.1.2.5
Low DC Current fault
state
6/INTEGER
AuxiliaryFault'NoFault=0,Fault=1,N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.6
Auxiliary fault state
7/INTEGER BUCFault'NoFault=0,Fault=1,N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.7 BUC fault state
8/INTEGER
Module1Fault'NoFault=0,Fault=1,N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.8
Module1 summary fault
state
9/INTEGER Module2Fault'NoFault=0,Fault=1,N/A=2 1.3.6.1.4.1.20712.2.1.3.1.2.9
Module2 summary fault
state
10/INTEGER Module3Fault'NoFault=0,Fault=1,N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.10
Module3 summary fault
state
11/INTEGER Module4Fault'NoFault=0,Fault=1,N/A=2 1.3.6.1.4.1.20712.2.1.3.1.2.11
Module4 summary fault
state
12/INTEGER CollingFanFault'NoFault=0,Fault=1,N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.12 Cooling fan fault state
13/INTEGER
LowForwardRFFault'NoFault=0,Fault=1,
N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.13
Low forward RF fault
state
14/INTEGER
HighReflectedRFFault'NoFault=0,Fault=1,
N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.14
High reflected RF fault
state
15/INTEGER
RFSwitch1Position'Fault=1,N/A=2,Pos1=3,
Pos2=4
1.3.6.1.4.1.20712.2.1.3.1.2.15
PF switch position1 /fault
state
16/INTEGER
RFSwitch2Position'Fault=1,N/A=2,Pos1=3,
Pos2=4
1.3.6.1.4.1.20712.2.1.3.1.2.16
PF switch position1 /fault
state
17/INTEGER FaultsPortbyte1'0..255 1.3.6.1.4.1.20712.2.1.3.1.2.17
Faults on logic port 1 raw
data
18/INTEGER FaultsPortbyte2'0..255
1.3.6.1.4.1.20712.2.1.3.1.2.18
Faults on logic port2 raw
data
19/INTEGER IOBoardHardwareID'0..255 1.3.6.1.4.1.20712.2.1.3.1.2.19
I/O Board hardware revi-
sion
20/INTEGER DigitalCoreBoardID'0..255
1.3.6.1.4.1.20712.2.1.3.1.2.20
DigiCore board hardware
revision
21/INTEGER UnitStandbyState'Online=1,Standby=0 1.3.6.1.4.1.20712.2.1.3.1.2.21
Current unit redundancy
state
22/INTEGER Reserved’0..255
1.3.6.1.4.1.20712.2.1.3.1.2.22
Reserved for factory use
only
23/INTEGER N1UnitState’Slave=0,Master=1,N1Off=2 1.3.6.1.4.1.20712.2.1.3.1.2.23 Unit N+1 state
24/INTEGER ExtFanFault’NoFault=0,Fault=1,N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.24
N+1 Cabinet Impeller
Fault
25/INTEGER N1SysFaults’0..16
1.3.6.1.4.1.20712.2.1.3.1.2.25
# of SSPA faults in N+1
system
26/INTEGER SelectedAtten(dBx10)’0,,200
1.3.6.1.4.1.20712.2.1.3.1.2.26
Actual SSPA attenuator
value
27/INTEGER Reserved’0..255
1.3.6.1.4.1.20712.2.1.3.1.2.27
Reserved for factory use
only
28/INTEGER Reserved’0..255
1.3.6.1.4.1.20712.2.1.3.1.2.28
Reserved for factory use
only
29/INTEGER PreAmpFault'NoFault=0,Fault=1,N/A=2
1.3.6.1.4.1.20712.2.1.3.1.2.29 PreAmp Fault