This set of Ethernet IP protocols is currently supported by the Teledyne Paradise Data-
com Universal M&C software package. The software is supplied on CD with the unit, or
can be download from company's web site, http://www.paradisedata.com.
9.6.1.2 Setting IPNet Interface
Before enabling the Ethernet IP interface, the following IP parameters need to be set:
IP Port address, Default Gateway, Subnet Mask, Receive IP Port and Lock IP address.
All IP related menu items consolidate under the Communication Setup menu.
1. Press the
Main Menu
key,
2. Select
2.Com.Setup
and press the
Enter
key,
3. Select
5.IP Setup
and press the
Enter
key.
The Lock IP address is a security measure. Setting this parameter either to 0.0.0.0 or
255.255.255.255 will allow any host to control the SSPA. Setting the parameter to the
specific address of the remote host will lock SSPA access to this host. Packets re-
ceived from other hosts will be ignored.
For other parameters (IP address, Gateway, Subnet, IP port) contact your network sys-
tem administrator for assistance.
Important!
If you are planning to access the SSPA RM via the Internet,
you must exercise appropriate security measures. It is strongly recom-
mended to put SSPA units behind a protective Firewall or set up a VPN
link for remote access.
After selecting the IP parameters, turn on IP interfaces through front panel:
1. Press the
Main Menu
key,
2. Select
2.Com.Setup
, press the
Enter
key;
3. Select
4.Interface
, press the
Enter
key;
4. Select
3.IPNet
and press the
Enter
key.
Ethernet Interface is now the primary remote control interface and the RS232/485 Main
port is disabled. The user may adjust any IP settings when the IPNet interface is turned
on, as needed, without losing IP link. New settings become effective only after a hard-
ware reset.
To perform a hardware reset, cycle power to the unit, or use the following sequence:
1. Press the
Main Menu
key;
2. Select
5.Options
and press the
Enter
key;
3. Select
6.Reset
and press the
Enter
key;
4. Select
3.Coms Only
and press the
Enter
key.