6 RU SSPA Chassis Operations Manual
2.4 After optional reboot, open the Command Prompt console window and enter:
C:\>IPCONFIG
This will display the IP settings:
0 Ethernet Adapter:
IP Address: 192.168.0.3
Subnet Mask:
255.255.255.0
Default Gateway:
2.5 You can now try to Ping your PC:
In Command Prompt window enter the following:
C:\>ping 192.168.0.3
This will display:
Pinging 192.168.0.3 with 32 bytes of data:
Reply from 192.168.0.3: bytes=32 time<10ms TTL=128
Reply from 192.168.0.3: bytes=32 time<10ms TTL=128
Reply from 192.168.0.3: bytes=32 time<10ms TTL=128
Reply from 192.168.0.3: bytes=32 time<10ms TTL=128
Ping statistics for 192.168.0.3:
Packets: Sent=4, Received=4, Lost=0 (0%loss),
Approximate round trip times I milli-seconds:
Minimum=0ms,
Maximum=0ms,
Average=0ms
Your network LAN card is now set up.
3. On the RM SSPA unit front panel, press the
Main Menu
key; select
2.Com.Setup
and press the
Enter
key; select
5.IPSetup
and press the
Enter
key; select
2.LocalIP
and press the
Enter
key; use the navigation keys to enter a valid IP address and press
the
Enter
key when complete.
Follow the same menu route to select the Subnet, Gateway, IPPort and IPLock items,
and set those parameters to: Subnet: 255.255.255.0; Gateway: 0.0.0.0; IPLock:
255.255.255.255; IPPort: 1038. Verify the selected parameters by selecting
1.IPInfo
and pressing the
Enter
key.