Service Manual
8-21
Field Replaceable Unit Disassembly/Assembly
8
6.
Remove the retainer holding the maintenance station's left pivot pin.
7.
Unpin the left and right ends of the maintenance station. Release the
maintenance station guide pin from the maintenance station cam gear.
Remove the maintenance station; pull out the air hoses and wiring
harness with it.
Caution
Do not nick or gouge the wiper or the vacuum chamber seal.
Reverse these steps to reinstall the maintenance station. If necessary, adjust the
maintenance station bracket to align the maintenance station parallel to the face
of the printhead. Refer to the Chapter 9 topic, “Maintenance station alignment”
on page 9-8.
Figure 8-17 Removing the maintenance station
9482-40
Maintenance
station