Service Manual
9-13
Checks and Adjustments
9
Ink loader sensor flag adjustment
1.
Inspect each sensor flag, ensuring that it is in the proper position, prior
to being actuated. The actuated portion of the flags, when not
actuated, should be perpendicular to the track of the ink sticks. Use a
1.5 mm hex wrench to adjust the flag on its shaft.
2.
Inspect the flag portion of each flag; the flag of the ink low sensor
should fully block the space between the sensor emitter and receiver
when there are no ink stick in the printer. Use a 1.5 mm hex wrench to
adjust the flag on its shaft.
The flag of the ink stick drop sensor is momentarily actuated when an
ink stick drops into the printhead. The flag of the ink low sensor
should fully block the space between the sensor emitter and receiver
only at that time. Use a 1.5 mm hex wrench to adjust the flag on its
shaft.
Figure 9-10 Adjusting sensor flags
9842-115
Ensure sensor,
when not activated,
is fully blocked
by flag
Ensure actuator is
perpendicular to
ink track
Ink low
sensor
Ink stick
drop sensor
Ensure actuator is
set to same angle
as its sensor