![Tektronix Phaser 600 Скачать руководство пользователя страница 219](http://html1.mh-extra.com/html/tektronix/phaser-600/phaser-600_service-manual_1078552219.webp)
Service Manual
8-47
Field Replaceable Unit Disassembly/Assembly
8
Sensors
Skew sensors
There are three skew sensors. Each is located on one of the paper guides of the
upper roller assembly.
1.
Turn off the printer. Leave the power cord plugged in to provide a
discharge path for static electricity.
2.
Open the top cover.
3.
Remove the inner plate (9 screws) from the inside of the top cover.
4.
Disconnect the ribbon cable leading to the sensor to be replaced.
5.
Locate and unclip the paper guide containing the skew sensor to be
replaced.
Tools required
■
#1 POSIDRIV® screwdriver
#0 POSIDRIV® screwdriver