8700
ATTENUATORS
Maintenance— 2440 Service
Table 6-6 (cont)
Channel 1 and Channel 2 Attenuators AT400 and AT300 (schematic diagram 9):
Testing Method:
THIS TEST IS ONLY PERFORMED USING EXTENDED CALIBRATION. With the Preamplifier set to
50 mV non-inverted, the Preamplifier gain test is repeated interactively using standard dc test voltages
applied to the CH 1 and CH 2 inputs. By adjusting the Preamplifier balance to give - 2 divisions, the
output is swung between - 2 (input grounded), and + 2 (input set to 0.2 V per div), divisions. The gain
control DAC is adjusted to achieve an output within specifications. The difference between the resulting
control DAC setting and the gain calibration constant measured at 50 mV per division (non-inverted) is
the attenuator gain constant. If a solution cannot be found, or if the resulting solution is more than a
2% gain error, the test result is set to FAIL. If the test fails, an attenuator gain of 0 (nominal) is stored
for the calibration constant under the assumption that the test setup may be in error. The test is
repeated for all three vertical attenuators (IX , 10X, and 100X) using input test voltages of 0.2 Vdc,
2 Vdc, and 20 Vdc.
Troubleshooting Procedure:
1.
Check that the correct test voltages are used for the ATTEN calibration step.
2.
Check that one audible click is heard when changing the VOLTS/DIV setting between 50 mV and
100 mV (1 OX attenuation) and between 500 mV and 1 V (100X attenuation). Also check that one
audible click is heard when changing the Vertical input coupling between DC and AC, and when
turning the fifty ohm input ON and OFF. Several clicks will normally be heard when switching in
and out of GND Coupling.
3.
If one and only one audible click was heard for each of the first four front-panel changes above,
then the circuitry that drives the four mag-latch relays in each attenuator is functioning properly by
switching the individual relays to the opposite latched position (the audible dick).
4.
Connect the output of a Standard Amplitude Calibrator to the vertical input of the failing channel
using coaxial cable with no terminator. Set the Standard Amplitude Generator output and the
VO LTS/DIV setting on the scope to the values given in the following table and check the signal
path between the Attenuator and the Preamplifier input of the failed channel. With a 10X probe on
the test scope, view the signal at the Preamp input pin. Use NOISE REJ Trigger Coupling and
20-M Hz Bandwidth on the test scope to clear up the trace noise and obtain a stable trigger. If only
one channel is bad, the other channel of the scope may be used to view the signal. The signal
amplitude out of the Attenuator and into the Preamp should be approximately 50 mV peak-to-peak
for each attenuator setting in the three ranges. A possible, but unlikely, source of a failure that is
not in the signal path between the Attenuator and the Preamp is a shorted capacitor (C414 or
C311) connecting to the Attenuator.
ATTENUATOR CHECK
Signal In
VOLTS/DIV
Signal Out
50 mV
2 mV to 50 mV
50 mV
0.5 V
100 mV to 500 mV
50 mV
5 V
1 V to 5 V
50 mV
5.
If one channel shows PASS flags on all the ATTEN tests, swap the Preamps between channels to
determine if the Preamplifier inputs are ok. If that swaps the problem, replace the faulty Preamp. If
the problem remains in the same channel, replace the defective Attenuator.
6-93
Содержание 2440
Страница 4: ......
Страница 12: ......
Страница 37: ...Specification 2440 Service Dimensions are in inches mm 4918 39 1 25 Figure 1 1 Dimensional drawing ...
Страница 38: ......
Страница 91: ...Theory of Operation 2440 Service 3 49 Figure 3 5 Simplified CCD architecture ...
Страница 120: ...Theory of Operation 2440 Service Figure 3 10 DC Restorer 3 78 ...
Страница 123: ...Theory of Operation 2440 Service SOURCE ACCEPTOR 4 9 1 7 1 2 3 81 Figure 3 11 GPIB data flow diagram ...
Страница 130: ...Theory of Operation 2440 Service 3 88 ...
Страница 136: ...Theory of Operation 2440 Service Figure 3 15 PWM Regulator and Inverter 3 94 ...
Страница 138: ...Theory of Operation 2440 Service Figure 3 16 PWM switching waveforms 3 96 ...
Страница 208: ......
Страница 322: ......
Страница 419: ......
Страница 423: ...2440 Service Figure 9 4b 2440 Block diagram part 2 6330 27 BLOCK DIAGRAM PART 2 ...
Страница 427: ......
Страница 428: ...2440 Service WAVEFORMS FOR DIAGRAM 1 6 2 8 5 3 2 ...
Страница 429: ......
Страница 432: ...2440 Service WAVEFORMS FOR DIAGRAM 2 BUS ISOLATED 6 6 0 3 4 9 ...
Страница 433: ...WAVEFORMS FOR DIAGRAM 2 ...
Страница 439: ......
Страница 445: ......
Страница 446: ...2440 Service WAVEFORMS FOR DIAGRAM 7 I I f f f NtITOT CHI r K I It MVIHi TRIGGER ON FALLING EDGE OF U832 PIN 8 MORE ...
Страница 450: ...2440 Service WAVEFORMS FOR DIAGRAM 8 6603 27 ...
Страница 455: ...W A V EFO R M S FOR D IAG RAM 11 WAVEFORMS FOR DIAGRAM 11 6603 29 ...
Страница 458: ...WAVEFORMS FOR DIAGRAM 12 ...
Страница 463: ...WAVEFORMS FOR DIAGRAM 14 ...
Страница 468: ...2440 Service W A VE FO R M S FOR DIAG RAM 17 TEST SCOPE TRIGGERED ON 126 6330 46 WAVEFORMS FOR DIAGRAM 17 ...
Страница 471: ... C N i u i t e x r 4 j u J l i 1 i 6 28 5 44 WAVEFORMS FOR DIAGRAM 18 ...
Страница 476: ...WAVEFORMS FOR DIAGRAM 20 ...
Страница 490: ...YES ...
Страница 492: ......
Страница 494: ......
Страница 499: ...YES ...
Страница 501: ......
Страница 502: ...2440 Service FIG 1 C A B IN E T ...
Страница 503: ......
Страница 510: ...2440 Service SISSVHO Z Old ...
Страница 511: ......
Страница 512: ...A12 2440 Service F IG 3 C IR C U IT BOARDS ...
Страница 513: ......
Страница 517: ...10 16 R E V J U L 1993 Replaceable Mechanical Parts ...
Страница 518: ...2440 Service ...
Страница 519: ...FIG 4 L V H V PWR SUPPLY ...
Страница 520: ...FIG 5 ACCESSORIES 2440 Service ...
Страница 521: ......
Страница 523: ......
Страница 529: ......
Страница 530: ......
Страница 531: ......