![Tektronix 2440 Скачать руководство пользователя страница 150](http://html1.mh-extra.com/html/tektronix/2440/2440_user-manual_1078860150.webp)
Performance Check and Functional Verification Procedure
2440 Service
3. Check CH 1 and CH 2 VOLTS/DIV Display and
Readout Accuracies. Check the A and B
TRIGGER LEVEL Readout Accuracies.
a.
Recall the Initial Front-Panel Setup, labeled “FPNL”
(see step i in “INITIAL S E T U P ” at the start of this
procedure). Make the following changes to the
front-panel setup:
Select:
Set:
VERTICAL M O DE
CH 2
Off
Select:
Set:
CH 1 C O U PLIN G /IN VER T
50 Q ON | OFF
OFF
Select:
Set:
CH 2 C O U PLIN G /IN VER T
50 f t ON | OFF
OFF
Select:
Set:
BANDWIDTH
20 MHz
On
Select:
Set:
TRIGGER M O DE
AUTO
On
b.
Connect the Calibration Generator’s STD A M PLITUDE
output to the CH 1 OR X input connector via a 50 f t
Coaxial Cable. Do not use a Termination.
c.
C H E C K -C H 1 and C H 2 VOLTS/DIV and TRIGG ER
LEVEL readout accuracies as follows:
1.
Set VOLTS/DIV control to the first position listed in
Table 4-2.
2.
Set the Calibration Generator STD AMPLITUDE
output level to the corresponding Standard Ampli
tude Out level in Table 4-2. Use the TRIGGER
LEVEL control as necessary to obtain a stable
display.
NOTE
To properly verify TRIGGER LEVEL readout
accuracy, the Calibration Generator’s output
must have rising and falling transition times
(10% to 90%) > 20 ns. No overshoot should
appear on the waveform.
3.
Verify that the Calibration Generator output meets
the requirements noted above.
4.
Use the VERTICAL POSITION control to set the
bottom of the signal 3 divisions below grati
cule center.
5.
Select CURSOR FU N CTIO N and set VOLTS on.
6.
Using the CURSOR/DELAY control, align the
selected cursor (segmented) with the bottom of the
displayed waveform.
7.
Push the CURSOR SELECT button to select the
other cursor (it will change from solid to seg
mented).
8.
Use the CURSOR/DELAY control to align this
cursor to the top of the waveform. Take care to use
the same reference points (top edge, bottom edge,
or center) of the waveform and cursor as in subpart
6
.
NOTE
For VOLTS/DIV Control Settings of 2 mV,
5
mV,
and 10 mV, select TRIGGER CPLG and set
NOISE REJ on. In addition, connect the Calibra
tion Generator STD AMPLITUDE output to the
C H I OR X Input connector via a 5 0 0 cable and
a 10X attenuator for the settings listed above.
For all other settings, set NOISE REJ off and
remove the 10X attenuator.
9.
C H E C K —That the voltage reading displayed by
the cursor readout is within the limits given in Table
4 -2 under the CURSOR VOLTS Readout Accura-
cy-NORMAL M O DE column.
10. Select STORAGE ACQ UIRE and set ENVE
LOPE on.
11. Using the CURSOR/DELAY control, readjust the
cursors as necessary to align them to the top or
bottom (discount noise) of the waveform. Press
CURSO R SELECT as needed to toggle between
the two cursors.
12. C H E C K —That the voltage reading displayed is
within the limits given in Table 4-2 under the
CURSO R VOLTS Readout Accuracy-ENVELOPE
M O DE column.
13. Set the ACQUIRE menu back to NORMAL on.
14. Set the TRIGGER LEVEL control at the most
positive voltage that produces a barely triggered,
jittering display for the positive ( + ) setting for the
slope switch.
15. C H E C K -T h e A Trigger Level readings (up
per-right corner of display) are within the limits
listed in the ( + ) Peak column under Limits-DC
Coupling in Table 4-2.
16. Set the TRIGGER LEVEL control at the most
negative voltage that produces a barely triggered,
jittering display for negative (-) setting for the
slope switch.
17. C H E C K -T h e A Trigger Level readings are within
the limits listed In the (-) Peak column under
Limits-DC Coupling in Table 4-2.
4-8
Содержание 2440
Страница 4: ......
Страница 12: ......
Страница 37: ...Specification 2440 Service Dimensions are in inches mm 4918 39 1 25 Figure 1 1 Dimensional drawing ...
Страница 38: ......
Страница 91: ...Theory of Operation 2440 Service 3 49 Figure 3 5 Simplified CCD architecture ...
Страница 120: ...Theory of Operation 2440 Service Figure 3 10 DC Restorer 3 78 ...
Страница 123: ...Theory of Operation 2440 Service SOURCE ACCEPTOR 4 9 1 7 1 2 3 81 Figure 3 11 GPIB data flow diagram ...
Страница 130: ...Theory of Operation 2440 Service 3 88 ...
Страница 136: ...Theory of Operation 2440 Service Figure 3 15 PWM Regulator and Inverter 3 94 ...
Страница 138: ...Theory of Operation 2440 Service Figure 3 16 PWM switching waveforms 3 96 ...
Страница 208: ......
Страница 322: ......
Страница 419: ......
Страница 423: ...2440 Service Figure 9 4b 2440 Block diagram part 2 6330 27 BLOCK DIAGRAM PART 2 ...
Страница 427: ......
Страница 428: ...2440 Service WAVEFORMS FOR DIAGRAM 1 6 2 8 5 3 2 ...
Страница 429: ......
Страница 432: ...2440 Service WAVEFORMS FOR DIAGRAM 2 BUS ISOLATED 6 6 0 3 4 9 ...
Страница 433: ...WAVEFORMS FOR DIAGRAM 2 ...
Страница 439: ......
Страница 445: ......
Страница 446: ...2440 Service WAVEFORMS FOR DIAGRAM 7 I I f f f NtITOT CHI r K I It MVIHi TRIGGER ON FALLING EDGE OF U832 PIN 8 MORE ...
Страница 450: ...2440 Service WAVEFORMS FOR DIAGRAM 8 6603 27 ...
Страница 455: ...W A V EFO R M S FOR D IAG RAM 11 WAVEFORMS FOR DIAGRAM 11 6603 29 ...
Страница 458: ...WAVEFORMS FOR DIAGRAM 12 ...
Страница 463: ...WAVEFORMS FOR DIAGRAM 14 ...
Страница 468: ...2440 Service W A VE FO R M S FOR DIAG RAM 17 TEST SCOPE TRIGGERED ON 126 6330 46 WAVEFORMS FOR DIAGRAM 17 ...
Страница 471: ... C N i u i t e x r 4 j u J l i 1 i 6 28 5 44 WAVEFORMS FOR DIAGRAM 18 ...
Страница 476: ...WAVEFORMS FOR DIAGRAM 20 ...
Страница 490: ...YES ...
Страница 492: ......
Страница 494: ......
Страница 499: ...YES ...
Страница 501: ......
Страница 502: ...2440 Service FIG 1 C A B IN E T ...
Страница 503: ......
Страница 510: ...2440 Service SISSVHO Z Old ...
Страница 511: ......
Страница 512: ...A12 2440 Service F IG 3 C IR C U IT BOARDS ...
Страница 513: ......
Страница 517: ...10 16 R E V J U L 1993 Replaceable Mechanical Parts ...
Страница 518: ...2440 Service ...
Страница 519: ...FIG 4 L V H V PWR SUPPLY ...
Страница 520: ...FIG 5 ACCESSORIES 2440 Service ...
Страница 521: ......
Страница 523: ......
Страница 529: ......
Страница 530: ......
Страница 531: ......