Error Messages
Page C-4
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
ST.TM.E10033.3
Error Message
Alarm
Fail
Action to Take
Mux Comms
Option Module 1 Comms (S8481 Video Input Module)
Option Module 2 Comms (S8477 Data Input Module)
Option Module 3 Comms (S10949 QPSK Modulator)
Option Module 4 Comms [S8489 or S10655 Module]
Power off MCE. Check Base Board 3ASI (Motherboard)
and reported Option Module are firmly seated in the
chassis. Power on MCE. If fault still present, call Service
Engineer.
Over Temperature
Check equipment ventilation slots are clear and
unobstructed; see Chapter 2 for details of ventilation
requirements. Check ambient air temperature is within
specified range; see Annex B. If fault still present, call
Service Engineer.
Over Voltage (5V)
Power supply unit output voltage requires adjustment.
Call Service Engineer.
PSU Voltage Sensor Failure
Real Time Clock Failure
SCC3 Serial Port
SCC4 Serial Port
Power MCE off, then back on again. If fault still
present, call Service Engineer.
SDI Anc. Data Error
An ancillary data checksum
error was detected in the digital
serial link connected to the
Encoder.
SDI Anc. Data Error Already
An ancillary data checksum
error was detected in the digital
serial link ‘upstream’ of the
Encoder.
SDI Anc. Data Unknown Error
The status of the ancillary data
flags is not known as the serial
link is received from a
transmitter that does not
support EDH.
SDI Full Field Error
A full field CRC error was
detected in the digital serial link
connected to the Encoder.
SDI Full Field Error Already
A full field CRC error was
detected in the digital serial link
‘upstream’ of the Encoder.
SDI Full Field Unknown Error
The status of the full field flags
is not known as the serial link
is received from a transmitter
that does not support EDH.
SDI Picture Error
An active picture CRC error
was detected in the digital
serial link connected to the
Encoder.
SDI Picture Error Already
An active picture CRC error
was detected in the digital
serial link ‘upstream’ of the
Encoder.
SDI Picture Unknown Error
The status of the active picture
flags is not known as the serial
link is received from a
transmitter that does not
support EDH.
Check the source of
the digital serial link
connected to the
Encoder SDI video
input, and any
equipment in the
signal path between
the source and the
Encoder, and all
related cables and
connectors. If the
transmitter (and/or
any intervening
devices) do not
support EDH, then
these messages do
not indicate a fault
with the Encoder.
Try to verify the
serial link using
another receiver. If
the link is verified as
OK then call Service
Engineer for
Encoder. If link is
suspect or cannot
be tested, then fault
may lie in data
transmitter or the
Encoder; investigate
further.
Temperature Sensor Failure
Power MCE off, then back on again. If fault still
present, call Service Engineer.
Содержание E5500
Страница 29: ...Introduction Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder Page 1 21 ST TM E10033 3 BLANK...
Страница 164: ...Equipment Description Page 4 2 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...
Страница 180: ...Equipment Description Page 4 18 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...
Страница 218: ...Error Messages Page C 2 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...
Страница 224: ...Error Messages Page C 8 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...