Operating the Equipment Locally
Page 3-94
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
ST.TM.E10033.3
Confirmation Screen
Symbol Rate
Specified Value Too High
Select <Enter> to Set to
Enter
Maximum : 37.500 Msym/s
Quit
Modulation Switched Off
If modulation is switched off, the option is used in the same way as
described for modulation switched on, except that the screens to switch
modulation off and then back on are not displayed.
FEC Rate Option
To access the FEC Rate option, press the FEC Rate softkey in the
Modulator
Menu
.
Pressing the FEC Rate softkey displays one of two screens, depending on
whether modulation is switched on or off when the softkey is pressed.
Modulation Switched On
The following screen is displayed. In order to change the FEC rate,
modulation must first be switched off. Press the Yes softkey to do this
automatically (and proceed to the next screen), or press the No (or Quit)
softkey to return to the menu.
Setup/Modulator Edit
F E C R a te
Yes
3 / 4
No
*
Switch Modulation OFF?
Quit
When modulation is switched off, the screen shown below is displayed. Use
the + and – softkeys to cycle through the available settings, then press
the Enter softkey to accept the new value. Changing the FEC rate affects
the automatic symbol rate, video bit-rate and video resolution calculations.
Table 3.75: FEC Rate Options
Selected Option
Description
1/2
FEC rate of 1/2.
2/3
FEC rate of 2/3.
3/4
FEC rate of 3/4.
5/6
FEC rate of 5/6.
7/8
FEC rate of 7/8.
Содержание E5500
Страница 29: ...Introduction Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder Page 1 21 ST TM E10033 3 BLANK...
Страница 164: ...Equipment Description Page 4 2 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...
Страница 180: ...Equipment Description Page 4 18 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...
Страница 218: ...Error Messages Page C 2 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...
Страница 224: ...Error Messages Page C 8 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...