Technical Specification
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
Page B-5
ST.TM.E10033.3
B.3
Control and Monitoring
B.3.1
Local Control
Local control is by means of the front panel keypad and LCD display. These
are used to display, select and change parameters, which are arranged on
a series of display menus (for details see Chapter 3, Operating the
Equipment Locally).
B.3.2
Remote Control
Ethernet 1 and 2
Table B.6: Ethernet Specification
Item
Specification
Safety Status:
SELV
Connector designation:
ETHERNET1 and ETHERNET 2
Connector type:
8-way RJ45 socket, 10 BaseT (ISO 882/3)
B.3.3
Alarm
Table B.7: Alarm Specification
Item
Specification
Safety status:
SELV
Connector designation:
ALARM
Connector type:
9-way D-type male
Alarm Contacts:
Changeover contacts (5
Ω
in common)
Fail contacts:
Changeover contacts (5
Ω
in common)
Reset contacts:
Short pins 9 and 5
B.3.4
Host Status
This is a test-only output and is not normally intended for operator use,
since status data is normally communicated via a remote controller, where
used.
Table B.8: Host Status Specification
Item
Specification
Safety status:
SELV
Connector designation:
HOST STATUS
Connector type:
9-way D-type male
Содержание E5500
Страница 29: ...Introduction Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder Page 1 21 ST TM E10033 3 BLANK...
Страница 164: ...Equipment Description Page 4 2 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...
Страница 180: ...Equipment Description Page 4 18 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...
Страница 218: ...Error Messages Page C 2 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...
Страница 224: ...Error Messages Page C 8 Instruction Manual evolution 5000 E5500 Mobile Contribution Encoder ST TM E10033 3 BLANK...