B–98
Operator Manual
If you are installing a printer on an active system, go through the following list
before connecting the Twinax cable(s).
•
Verify that the printer address matches the one given it on the host and
that no addresses are duplicated anywhere on the line. You can check the
address of the printer by accessing the HELP Menu on your printer
control panel and printing out a Control Panel Selections Printout (see
Chapter 3).
•
Make sure the printer is turned OFF.
•
Terminate the device immediately up cable (between the printer and the
host) from the printer.
•
Any jobs going to devices down cable (between the printer and the end of
the network) must be put on HOLD.
•
Place any devices that are down cable from the printer OFFLINE.
Now connect the cable from the out connector of the up cable device to either
side of the Host Connector Smart T and if there are devices down cable, connect
the cable going to them to the other side of the Smart T. The Smart T
automatically takes care of terminating the Twinax line or allowing throughput of
data to devices located down cable from the printer.
Coax Interface
This interface is optional and requires the installation of an additional interface module.
Make
sure that the printer is turned off. To connect to a Coax system, use the BNC
adapter (a DB-15 to Coax). Connect the adapter to the Host Interface plug on
the printer I/O. The Coax interface allows a maximum of 5,000 feet (1.5 km)
from the host computers to the printer.
Figure B - 2. Twinax Smart “T” Adaptor
Your Twinax hookup is now complete and it is time to test your printer to verify
its operation. Load your printer with paper and an ink ribbon. Run the IBM
printer verification test. If the test is successful, your installation is complete.
Figure B - 3. BNC Coax adapter
Optional Interfaces
Содержание LGe06
Страница 1: ...Operator Manual 1 LG Series Operator Manual Serial Parallel LAN...
Страница 24: ...1 24 Operator Manual Blank Page...
Страница 88: ...3 88 Operator Manual Blank Page...
Страница 96: ...A 96 Operator Manual Blank Page...
Страница 107: ...Blank Page...
Страница 108: ...4500 Daly Drive Suite 100 T 703 833 8700 Chantilly VA 20151 F 703 222 7629 www tallygenicom com...