C–102
Operator Manual
Power Supply
The printer requires single phase, 47 to 63 Hz. 90 to 264 VAC input power. The
printer’s universal power supply automatically adjusts to the correct values. A
fuse is provided to interrupt power to the power supply. The following table
gives typical current values.
6306 Current/Wattage Requirements @ Nominal Voltage
AC Volts
Freq. Average
Peak
Average
Average
(RMS) (Hz)
Operating
Operating
Idle (<5 min.) Idle (>5 min.)
110
50
1.0 A/055 W
2.3 A/250 W
0.3 A/35 W
0.2 A/19 W
110
60
1.0 A/105W
2.3 A/250W
0.3 A/35W
0.2 A/19 W
220
50
0.5 A/105W
1.2 A/250W
0.2 A/35W
0.1 A/19W
6312 Current/Wattage Requirements @ Nominal Voltage
AC Volts
Freq. Average
Peak
Average
Average
(RMS)
(Hz)
Operating
Operating
Idle (<5 min.) Idle (>5 min.)
110
50
2.2 A/250 W
4.6 A/510 W
0.4 A/36 W
0.2 A/18 W
110
60
2.2 A/250W
4.6 A/510W
0.4 A/36W
0.2 A/18 W
220
50
1.1 A/250W
2.3 A/510W
0.2 A/36W
0.1 A/18W
Heat Load Contribution
The average heat load contribution to the environment is approximately 735
BTUs per hour (215 Watts). The minimum heat load contribution is approxi-
mately 100 BTUs per hour (30 watts). The maximum is 2050 BTUs per hour
(600 Watts), under continuous full-load printing conditions.
Printing Conditions (110 VAC/60 Hz)
Wattage
BTU/Hr
Power On, not printing
55 W
188
100% Uppercase Rolling ASCII
400W
1370
Black Page Plot
600 W
2050
Power Supply and Heat Load
Содержание LGe06
Страница 1: ...Operator Manual 1 LG Series Operator Manual Serial Parallel LAN...
Страница 24: ...1 24 Operator Manual Blank Page...
Страница 88: ...3 88 Operator Manual Blank Page...
Страница 96: ...A 96 Operator Manual Blank Page...
Страница 107: ...Blank Page...
Страница 108: ...4500 Daly Drive Suite 100 T 703 833 8700 Chantilly VA 20151 F 703 222 7629 www tallygenicom com...