3–64
Operator Manual
Config Menu
⇒
Codes
Code 7F
This parameter allows you to dictate how the printer will react when it receives a
Hexadecimal code 7F. The default value depends on the emulation. (See the
Emulation Parameter, presented earlier in this chapter.)
Ignore:
The code is ignored.
Delete Char:
The previous character is deleted.
Delete Buffer:
The previous characters on the current print line are deleted.
Space:
A Space character is substituted.
Fill:
A Fill character is substituted.
Print 80 - 9F Hex
This parameter defines whether locations 80 through 9F Hex are to be treated as
control characters or printable characters. The function of the control characters
in this area depends on the emulation. The options are ON (printable charac-
ters) – the default, or OFF (control characters).
Ignore Char
This parameter allows you to select a character that will be ignored in the incom-
ing data stream. Ignore Char functions in all emulations and non-downloadable
print modes. It does not function in plot mode, font download, or VFU down-
load. Options are 0-255, referring to the decimal value of any 8-bit character, or
OFF. Default is OFF.
Sub Char From
This parameter allows you to select a character that will be replaced by the
character designated by the Sub Char To parameter. It functions in all emulations
and non-downloadable print modes. It does not function in plot mode, font
download, or VFU download. Default is OFF.
Sub Char To
This parameter allows you to select the character that will replace the character
designated by Sub Char From. It functions in all emulations and non-
downloadable print modes. It does not function in plot mode, font download, or
VFU download. Default is OFF.
PTX SFCC (Only affects the Printronix P5000 emulation)
Defines the Special Function Control Character used by the Printronix P5000
emulation. The decimal value of the ASCII character code is entered. The default
value is 1 (SOH).
PTX ALS (Only affects the Printronix P5000 emulation)
Defines the single line Alternate Line Spacing used by the ACK (Hex 06) com-
mand in the Printronix P5000 emulation. The options are 8 or 10.3 which define
the line density. The default value is 8.
Содержание LGe06
Страница 1: ...Operator Manual 1 LG Series Operator Manual Serial Parallel LAN...
Страница 24: ...1 24 Operator Manual Blank Page...
Страница 88: ...3 88 Operator Manual Blank Page...
Страница 96: ...A 96 Operator Manual Blank Page...
Страница 107: ...Blank Page...
Страница 108: ...4500 Daly Drive Suite 100 T 703 833 8700 Chantilly VA 20151 F 703 222 7629 www tallygenicom com...