Servicing Motherboard Components
83
▼
Identify Faulty FB-DIMMs Using the
show
faulty
Command
The ILOM
show faulty
command displays current system faults, including
FB-DIMM failures.
●
Enter
show faulty
at the
->
prompt.
Related Information
■
“Identify Faulty FB-DIMMs Using the FB-DIMM Fault Locator Button” on page 83
▼
Identify Faulty FB-DIMMs Using the FB-DIMM
Fault Locator Button
Use the FB-DIMM Fault Locator button to identify faulty FB-DIMMs.
Note –
The location of this button is shown in
FIGURE: FB-DIMM Fault Locator
Button on the Motherboard on page 84
. It is marked
SW6500
.
1. Extend the server to the maintenance position.
See
“Extend the Server to the Maintenance Position” on page 63
.
2. Disconnect power from the server.
See
“Removing Power From the System” on page 60
.
3. Remove the top cover.
See
“Remove the Top Cover” on page 67
.
4. Open the air duct to gain to access the FB-DIMM Fault Locator button.
5. Press the FB-DIMM Fault Locator button on the motherboard.
This will cause an amber LED associated with the faulty FB-DIMM to light for a
few minutes.
->
show faulty
Target | Property
| Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BR1/CH0/D0
/SP/faultmgmt/0 | timestamp | Dec 21 16:40:56
/SP/faultmgmt/0/ | timestamp | Dec 21 16:40:56 faults/0
/SP/faultmgmt/0/ | sp_detected_fault | /SYS/MB/CMP0/BR1/CH0/D0
faults/0 | | Forced fail(POST)
Содержание SPARC T5120
Страница 4: ......
Страница 34: ...18 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart...
Страница 72: ...56 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 171: ...Servicing Boards and Components 155 FIGURE Installing a Hard Drive Backplane in a Sun SPARC Enterprise T5120 Server...
Страница 190: ...174 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 224: ...208 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...