48
Sun SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009
3. Use the
clear_fault_action
property of the FRU to clear the fault from the
service processor.
4. Clear the fault from all persistent fault records.
In some cases, even though the fault is cleared, some persistent fault information
remains and results in erroneous fault messages at boot time. To ensure that these
messages are not displayed, run the Solaris command
fmadm repair
, specifying
the UUID of the erroneous message.
Viewing Solaris OS Messages
These topics explain how to display OS messages from the message buffer and log
files maintained by Solaris OS.
■
“Check the Message Buffer” on page 49
■
“View the System Message Log Files” on page 49
▼
Check the Message Buffer
1. Log in as superuser.
2. Type the
dmesg
command:
The
dmesg
command displays the most recent messages generated by the system.
▼
View the System Message Log Files
The error logging daemon,
syslogd
, automatically records various system
warnings, errors, and faults in message files. These messages can alert you to system
problems such as a device that is about to fail.
->
set /SYS/MB/CMP0/BR0/CH0/D0 clear_fault_action=True
Are you sure you want to clear /SYS/MB/CMP0/BR0/CH0/D0 (y/n)?
y
Set ’clear_fault_action’ to ’true
#
fmadm repair 7ee0e46b-ea64-6565-e684-e996963f7b86
#
dmesg
Содержание SPARC T5120
Страница 4: ......
Страница 34: ...18 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart...
Страница 72: ...56 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 171: ...Servicing Boards and Components 155 FIGURE Installing a Hard Drive Backplane in a Sun SPARC Enterprise T5120 Server...
Страница 190: ...174 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 224: ...208 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...