Detecting and Managing Faults
45
PSH-detected faults also cause the Service Required LED to be turned on.
Use the ILOM
show faulty
command to view summary information about the
fault. See
“Faults Displayed by
show faulty
” on page 29
for more information
about the
show faulty
command.
Faults detected by the Solaris PSH facility are also reported through service processor
alerts.
Note –
You must be logged in to the ALOM CMT shell to see Solaris PSH fault
alerts.
▼
Identify PSH-Detected Faults With
fmdump
The
fmdump
command displays the list of faults detected by the Solaris PSH facility
and identifies the faulty FRU for a particular EVENT_ID (UUID).
Note –
The information
fmdump
displays is taken from the PSH event log, which
retains the fault data after the fault has been repaired. For that reason,
fmdump
cannot be used to verify that a FRU replacement has cleared a fault. Instead, use the
fmadm faulty
command to verify that the fault has cleared.
acceptable levels. Refer to http://sun.com/msg/SUN4V-8000-DX for more
information.
AUTO-RESPONSE: Pages of memory associated with this memory module are being
removed from service as errors are reported.
IMPACT: Total system memory capacity will be reduced as pages are retired.
REC-ACTION: Schedule a repair procedure to replace the affected memory module.
Use fmdump -v -u <EVENT_ID> to identify the module.
SC Alert: Most detected fault, MSGID: SUN4v-8000-DX
Содержание SPARC T5120
Страница 4: ......
Страница 34: ...18 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart...
Страница 72: ...56 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 171: ...Servicing Boards and Components 155 FIGURE Installing a Hard Drive Backplane in a Sun SPARC Enterprise T5120 Server...
Страница 190: ...174 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 224: ...208 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...