Servicing Hard Drives
75
4. At the Solaris prompt, type the
cfgadm -al
command. This will list all drives
in the device tree, including drives that are not configured.
This command should identify the
Ap_id
for the hard drive you plan to remove,
as shown below.
5. Type
cfgadm -c configure
command to configure the disk.
For example, the following shows drive
c0:dsk/c1t1d1
being configured:
where
c0::sd1
is the disk that you want to configure.
6. Wait until the blue Ready-to-Remove LED is no longer lit on the drive that you
installed.
#
cfgadm -al
Ap_id
Type
Receptacle
Occupant
Condition
c0 scsi-bus connected configured unknown
c0::dsk/c1t0d0 disk connected configured unknown
c0::sd1 disk connected unconfigured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
usb0/3 unknown empty unconfigured ok
usb1/1 unknown empty unconfigured ok
usb1/2 unknown empty unconfigured ok
usb1/3 unknown empty unconfigured ok
usb2/1 unknown empty unconfigured ok
usb2/2 unknown empty unconfigured ok
usb2/3 unknown empty unconfigured ok
usb2/4 unknown empty unconfigured ok
usb2/5 unknown empty unconfigured ok
usb2/6 unknown empty unconfigured ok
usb2/7 unknown empty unconfigured ok
usb2/8 unknown empty unconfigured ok
----------------------------
#
cfgadm -c configure c0::sd1
Содержание SPARC T5120
Страница 4: ......
Страница 34: ...18 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart...
Страница 72: ...56 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 171: ...Servicing Boards and Components 155 FIGURE Installing a Hard Drive Backplane in a Sun SPARC Enterprise T5120 Server...
Страница 190: ...174 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...