Detecting and Managing Faults
47
3. Follow the suggested actions to repair the fault.
▼
Clear PSH-Detected Faults
When the Solaris PSH facility detects faults, the faults are logged and displayed on
the console. In most cases, after the fault is repaired, the corrected state is detected by
the system, and the fault condition is repaired automatically. However, this repair
should be verified. In cases where the fault condition is not automatically cleared, the
fault must be cleared manually.
1. After replacing a faulty FRU, power on the server.
2. At the ILOM prompt, use the
show faulty
command to identify PSH detected
faults.
PSH-detected faults are distinguished from other kinds of faults by the presence of
a
sunw-msg-id
and
uuid
property.
The next step depends on whether or not a fault was reported.
■
If
show faulty
does not report a fault, stop. Do not go on to the next step.
■
If a fault is reported, perform
Step 3
and
Step 4
.
Impact
System performance may be affected.
Suggested Action for System Administrator
Schedule a repair procedure to replace the affected CPU, the
identity of which can be determined using fmdump -v -u
<EVENT_ID>.
Details
The Message ID: SUN4V-8000-JA indicates diagnosis has
determined that a CPU is faulty. The Solaris fault manager
arranged an automated attempt to disable this CPU....
->
show faulty
Target | Property | Value
--------------------+------------------------+------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BR0/CH1/D0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/
| uuid
| 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
Содержание SPARC T5120
Страница 4: ......
Страница 34: ...18 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart...
Страница 72: ...56 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 171: ...Servicing Boards and Components 155 FIGURE Installing a Hard Drive Backplane in a Sun SPARC Enterprise T5120 Server...
Страница 190: ...174 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 224: ...208 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...