Sun SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009
▼
Power Off the Server (Power Button - Graceful)
●
Press and release the Power button.
If necessary, use a pen or pencil to press the Power button.
Related Information
■
“Power Off the Server (Service Processor Command)” on page 60
■
“Power Off the Server (Emergency Shutdown)” on page 62
▼
Power Off the Server (Emergency Shutdown)
Caution –
All applications and files will be closed abruptly without saving changes.
File system corruption might occur.
●
Press and hold the Power button for four seconds.
Related Information
■
“Power Off the Server (Service Processor Command)” on page 60
■
“Power Off the Server (Power Button - Graceful)” on page 62
▼
Disconnect Power Cords From the Server
●
Unplug all power cords from the server.
Caution –
Because 3.3v standby power is always present in the system, you must
unplug the power cords before accessing any cold-serviceable components.
Positioning the System for Servicing
These topics explain how to position the system so you can access the components
that need servicing.
■
“Extend the Server to the Maintenance Position” on page 63
■
“Remove the Server From the Rack” on page 64
Содержание SPARC T5120
Страница 4: ......
Страница 34: ...18 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart...
Страница 72: ...56 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 171: ...Servicing Boards and Components 155 FIGURE Installing a Hard Drive Backplane in a Sun SPARC Enterprise T5120 Server...
Страница 190: ...174 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 224: ...208 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...