Servicing Motherboard Components
89
Note –
As soon as the power cords are connected, standby power is applied.
Depending on how the firmware is configured, the system might boot at this time.
Related Information
■
“Remove FB-DIMMs” on page 85
■
“Verify Successful Replacement of Faulty FB-DIMMs” on page 89
▼
Verify Successful Replacement of Faulty
FB-DIMMs
1. Access the ILOM
->
prompt.
Refer to the
Sun Integrated Lights Out Manager (ILOM) 3.0 Supplement for Sun
SPARC Enterprise T5120 and T5220 Servers
for instructions.
2. Use the
show faulty
command to determine how to clear the fault.
■
If
show faulty
indicates a POST-detected the fault go to
Step 3
.
■
If
show faulty
indicates a host-detected fault (output displays a UUID), go
directly to
Step 4
.
3. Use the
set
command to enable the FB-DIMM that was disabled by POST.
In most cases, replacement of a faulty FB-DIMM is detected when the service
processor is power cycled. In those cases, the fault is automatically cleared from
the system. If
show faulty
still displays the fault, clear it with the
set
command.
4. Perform the following steps to verify the repair:
a. Set the virtual keyswitch to
diag
so that POST will run in Service mode.
b. Power cycle the system.
->
set /SYS/MB/CMP0/BR0/CH0/D0 component_state=Enabled
->
set /SYS/keyswitch_state=Diag
Set ‘keyswitch_state’ to ‘Diag’
->
stop /SYS
Are you sure you want to stop /SYS (y/n)?
y
Stopping /SYS
Содержание SPARC T5120
Страница 4: ......
Страница 34: ...18 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart...
Страница 72: ...56 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 171: ...Servicing Boards and Components 155 FIGURE Installing a Hard Drive Backplane in a Sun SPARC Enterprise T5120 Server...
Страница 190: ...174 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 224: ...208 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...