118
Sun SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009
Note –
The firmware configuration variable settings are not stored in the SCC
module. If you replace the motherboard, these settings will become the factory
default settings. If possible, keep a record of any firmware variables that have been
changed from the factory default values so you can configure the new motherboard
with those settings.
Related Information
■
“Remove the Motherboard Assembly” on page 118
■
“Install the Motherboard Assembly” on page 120
▼
Remove the Motherboard Assembly
Caution –
This procedure requires that you handle components that are sensitive to
electrostatic discharge. This discharge can cause server components to fail.
1. Run the ALOM CMT
showrc
command and make a note of any SP variables
that have been modified from the factory default.
2. Stop Solaris OS to get the OpenBoot PROM prompt.
3. Run the
printenv
command to make a note of any OpenBoot PROM variables
that have been modified
4. Power off the server.
See
“Removing Power From the System” on page 60
.
5. Remove the server from the rack.
See
“Remove the Server From the Rack” on page 64
.
6. Attach an antistatic wrist strap.
7. Remove the top cover.
See
“Remove the Top Cover” on page 67
.
8. Remove the air duct.
See
“Remove the Air Duct” on page 100
.
9. Remove all PCIe/XAUI riser assemblies.
See
“Remove a PCIe/XAUI Riser” on page 102
.
Содержание SPARC T5120
Страница 4: ......
Страница 34: ...18 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart...
Страница 72: ...56 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 171: ...Servicing Boards and Components 155 FIGURE Installing a Hard Drive Backplane in a Sun SPARC Enterprise T5120 Server...
Страница 190: ...174 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 224: ...208 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...