Detecting and Managing Faults
31
PSH Technology
Related Information
■
“Clear FRU Faults Manually” on page 31
■
“Display FRU Information With the
show
Command” on page 32
▼
Clear FRU Faults Manually
Use the
clear_fault_action
property of a FRU to manually clear faults recorded
in a FRU PROM. There are two conditions where this step may be needed:
■
To clear a fault diagnosed by the predictive self-healing feature without replacing
the faulty FRU.
■
To clear a fault that the service processor was unable to clear following a FRU
replacement.
Note –
This procedure clears the fault from the service processor but not from the
host. If the fault persists in the host, it must be manually cleared.
●
At the
->
prompt, enter the
clear_fault_action
property.
Related Info
■
“Clear PSH-Detected Faults” on page 47
->
show faulty
Target
| Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BR0/CH1/D0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/
| uuid
| 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
->
set /SYS/MB/CMP0/BR0/CH0/D0 clear_fault_action=True
Are you sure you want to clear /SYS/MB/CMP0/BR0/CH0/D0 (y/n)?
y
Set ’clear_fault_action’ to ’true’
Содержание SPARC T5120
Страница 4: ......
Страница 34: ...18 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart...
Страница 72: ...56 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 171: ...Servicing Boards and Components 155 FIGURE Installing a Hard Drive Backplane in a Sun SPARC Enterprise T5120 Server...
Страница 190: ...174 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...
Страница 224: ...208 Sun SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009...