33
Programming and installation manual Careline Anna / Careline GSM
Doc. no. 32-022-03-01 EN v6
Dial tone detection
Specifies whether the Careline Anna/GSM shall detect the dial tone or not, before a telephone number is
dialled. If you specify
<Activated>
the carephone waits until it hears a dialling tone before the number is
rolled. If you specify
<Not activated>
the Careline Anna/GSM waits a couple of seconds before the
number is rolled. The factory default is
<Activated>.
This setting only applies to the analogue alarm calls.
Mute dialling
Specify if you want to hear the numbers being dialled and the carephone's communication with the alarm
receiver in the loudspeaker on the carephone or not. The factory default is
<Not activated>.
Polarity change
Specify if the carephone shall detect alternation on the telephone line. Factory default is
<Activated>.
Incoming call
Control of the features used when someone calls to the carephone.
>Transmitter Answer< >Ringing signal< >Tele prog signal<
Transmitter Answer
If the transmitter answer is activated, the care recipient can answer an incoming call by pressing the alarm
transmitter. The carephone then acts as a standard speakerphone. By repressing the alarm transmitter the
telephone call is terminated. In Careline GSM you can choose to activate transmitter answer for the
telephone line, the GSM connection or both.
Ringing signal
If the incoming call ringing signal is activated, the carephone also rings when someone calls to a care
recipient.
Tele programming signal
Specifies after how many ringing signals Careline Anna/GSM shall respond in the remote programming
mode when dialling to the care recipient. The number of signals should normally be 0, which means that
the carephone never answers the call. Possible values are 0 to 255. Factory default is 0.
Timers
Has a submenu, where you can check all alarms that are controlled by a timer.
>Test Alarm< >Link Test< >Away function< >Mains failure< >Mains return < >Passive Alarm<
Test Alarm
Has a submenu consisting of:
>Interval< >First Alarm< >Next Alarm<
>Interval<
is a menu choice where you specify how many hours between test alarms. If you want the
carephone to sound the test alarm once a day, then enter the value 24. If 0 is entered the test alarm
function is deactivated. The factory default is 24.
>First Alarm<
determines how many hours before the first test alarm is sent. The value can be
between 0 and 240, but in practice between 0 and 24. The factory default is 24.
>Next Alarm<
is a menu choice where you can read the value in hours until the next test alarm. The
value cannot be changed in this menu, only read.