Programming and installation manual Careline Anna / Careline GSM
Doc. no. 32-022-03-01 EN v6
5.1.2
Basic programming of Careline Anna/GSM
Follow these instructions to provide the carephone with the obligatory information about the alarm code,
telephone number, etc.
Note! In order to carry out the basic programming it is necessary to have pre-
programmed the hand terminal.
Connect the hand terminal to the back of the carephone by disconnecting the mains adapter from the
carephone and instead put the narrow end of the red cable into this socket. The other end of the red wire
should be connected to the hand terminal's middle socket.
Plug the mains adapter into the hand terminal's smallest socket.
Turn on the carephone by setting the switch to 1. (If it was already turned on, restart it.) The hand terminal
now connects automatically.
Choose menu >
Alarm codes
<
with the arrow keys
on the hand terminal, press
Yes
Delete any old alarm code with the
-
button.
Enter the new alarm code, press
Yes
Choose menu >
Quit
<
with the arrow keys
on the hand terminal, press
Yes
For the question of whether you want to transfer the changes to TT, press
Yes
.
Wait until the transfer has finished.
Disconnect the hand terminal and reconnect the mains adaptor to the carephone.
Test that the alarm works by pressing the red button on the carephone.
5.1.3
Program an alarm transmitter with the hand terminal
To program the alarm transmitter to the Careline Anna/GSM with the hand terminal, do the following (this is done
to a carephone that is already pre-programmed with the standard settings):
Connect the hand terminal to the back of the carephone by disconnecting the mains adapter from the
carephone and instead put the narrow end of the red cable into this socket. The other end of the red cable
should be connected to the hand terminal's middle socket.
Plug the mains adapter into the hand terminal's smallest socket.
Turn on the carephone by setting the switch to 1. (If it was already turned on, restart it.) The hand terminal
now connects automatically.
When the main menu appears, go to >
Programming
<, press
Yes
Enter code
1812
Choose menu >
Program
<, press
Yes
Choose menu >
Transmitters
<, press
Yes
Choose transmitter location (see table below), press
Yes
Press T (the carephone then beeps 4 times) and activate the accessory.
8 digits appear under
New value
. (It also states <
OK
> or<
Low
> which indicates whether the battery in
the accessory is OK or if it needs changing.)
Hold down the right arrow button until the display states <
sending
>.
Wait until the text <
sending
> disappears, press
Yes
Press
No
three times.
Choose >
Quit<
, press
Yes
Enter
No
to the question Send changes to phone? Press Yes/No .
The accessory is now installed in the carephone.
Disconnect the hand terminal and reconnect the mains adaptor to the carephone.
Try to send an alarm from the programmed accessory.