EN
48
763.134 Z02 1913 coolcept_fleX
Factory setting
Resetting the data to factory settings deletes the following data:
•
Yield data
•
Event messages
•
Date and time
•
Country setting
•
Display language
•
Network settings
The inverter restarts. The initial commissioning must be performed again.
All parameters
This menu item allows the change of further ENS parameters (only service technician).
8
Web portal
Automatic start of the transmission of unencrypted data.
After establishing the network connection, the inverter automatically starts
data transmission to the server. If automatic transmission is not wanted:
►
Remove network cable.
Or:
►
Deactivate data transmission in "Settings" > "Network".
With the monitoring portal sunCloud, permanently free of charge, online monitoring of
PV generators is easy and comfortable. Registration of the operator and the system in the
sunCloud portal is possible at:
Operator guidance in the sunCloud portal is easy and allows intuitive navigation. After reg-
istering and connecting the TCP/IP interface LAN to a PC, the portal displays data (e.g.
yield data and performance of the connected PV generator).
The local network settings for the connection to the server have been set on the inverter.
Setting the local network can be done automatically or manually:
•
Automatic: if the DHCP prescribes the IP address in the network automatically, no set-
tings are required on the inverter.
•
Manual: if the IP address in the network is not assigned automatically, the IP address
must be set manually on the inverter in "Settings" > "Network" (refer to section 7.4.4).
The URL of the web portal is saved permanently in the inverter and cannot be changed.