EN
26
763.134 Z02 1913 coolcept_fleX
100 V to 127 V grid voltage
DANGER
Voltage
There is a risk of death by electrocution when connecting the phases L1, L2,
or L3 to PE or N.
►
Follow the safety instructions and warning notices in chapter 5.
The structure of 100 V to 127 V grid voltages differs from that of 220 V to 240 V grid volt-
ages as it is not a 1-phase but a 2 or 3-phase grid.
1
AC plug housing
2
PE connection
3
L1 connection (outer conductor)
4
L2 connection (outer conductor)
Connecting AC plug to 2-phased grid
Connect the inverter between the L1 and L2 outer conductors.
1. Connect the N and L connection of the AC plug (1) between the L1 (3) and L2 (4)
outer conductors of the grid cable.
2. Connect PE cable to PE connection on the AC plug.
Connecting AC plug to 3-phased grid (not depicted)
In the 3-phase grid, there are 3 outer conductors in the cable:
1. Connect N and L connections of the AC plug between any 2 outer conductors
(between L1 and L2, or L1 and L3, or L2 and L3).
2. Connect PE cable to PE connection on the AC plug.