EN
763.134 Z02 1913 coolcept_fleX
61
StecaGrid
3011_2
StecaGrid
3611_2
StecaGrid
4611_2
Highest overcurrent protection at
the output
40 A
40 A
57 A
Characterisation of the operating behaviour
Max. efficiency
97.00 %
97.00 %
97.40 %
European efficiency
96.30 %
96.30 %
96.90 %
MPP efficiency
> 99.7 % (static), > 99 % (dynamic)
Internal consumption
< 20 W
Power derating at full power from
45 °C (T
amb
)
45 °C (T
amb
)
40 °C (T
amb
)
Safety
Isolation principle
No galvanic isolation, without transformer
Grid monitoring
Yes, integrated
Residual current monitoring
Yes, integrated (the inverter cannot cause a DC
residual current due to the design)
Protection class
Protection class 2 (RCD type A sufficient)
Operating conditions
Area of application
Indoors, outdoors (degree of soiling 3)
Climate category i.a.w.
IEC 60721-3-4
4K4H
Ambient temperature
-25 °C to +60 °C
Storage temperature
-30 °C to +80 °C
Relative humidity
0 % to 100 %, non-condensing
Noise emission (typical)
31 dB(A)
Equipment and design
Degree of protection
IP 65
Overvoltage category
III (AC), II (DC)
DC connection
Phoenix Contact SUNCLIX (2 pair), mating plugs
included in the scope of delivery