Fault elimination
Event messages indicate faults: the display will be flashing red and a text will describe the
fault present.
Typical display of an event message
Event messages contain the following information:
1
Event message type
2
Date/time of the event message
3
Note on the status of the event:
Active
= fault is still present
Date/time
= fault was eliminated at the indicated time
4
Cause of the fault
5
Consecutive number / total number in the list of events
6
Acknowledged / not acknowledged fault
Events are acknowledged by pressing the "ESC" or "
" operating buttons.
9.1
Event message type
Information
The inverter has detected an error which does not impair feed-in. There is no need for the
user to intervene.
Warning
The inverter has detected an error which may cause reduced yields. It is recommended to
eliminate the cause of error.
Error
The inverter has detected a serious error. The inverter does not feed in as long as the error
is present.
Inform the installer.