EN
763.134 Z02 1913 coolcept_fleX
25
Inverter
Cable cross section
AC cable
Power loss
(with 10 m cable
length)
Circuit breaker
StecaGrid 3011
and
StecaGrid 3011_2
2.5 mm
²
25 W
B16 or B25
4.0 mm
²
15 W
StecaGrid 3611
and
StecaGrid 3611_2
2.5 mm
²
35 W
B25
4.0 mm
²
23 W
StecaGrid 4611_2
2.5 mm
²
56 W
B25
4.0 mm
²
35 W
4.3.2 Residual current circuit breaker
If the local installation specifications prescribe the installation of an external residual
current circuit breaker, install a residual current circuit breaker. In accordance with
IEC 62109-1, a type A residual current circuit breaker is adequate.
4.3.3 Assembling the AC plug
NOTE
If the instructions of the plug manufacturer are not followed when connecting
the AC plug, the cable and the device may be damaged.
►
Follow the instructions of the plug manufacturer.
Assemble the AC plug (refer to section "Assembly instruction for AC plug") and connect it.
220 V to 240 V grid voltage
Connect conductors N, L, and PE on the AC plug in 1-phase grid with 220 V to 240 V grid
voltage.
1
AC plug housing
2
PE connection
3
L connection (outer conductor)
4
N connection (outer conductor)