The Operator Station
5-7
605C Frequency Inverter
Alert Message Displays
A message will be displayed on the Operator Station when either:
•
A requested operation is not allowed.
The top line details the illegal operation, while the
bottom line gives the reason or cause. See example
opposite.
•
The Inverter has tripped.
The top line indicates a trip has occurred while the
bottom line gives the reason for the trip. See
example opposite.
Most messages are displayed for only a short period, or for as long as an illegal operation is
tried, however, trip messages must be acknowledged by pressing the
E
key.
Experience will show how to avoid most messages. They are displayed in clear, concise
language for easy interpretation. Refer to Chapter 7: “Trips and Fault Finding” for trip messages
and reasons.
The PROG Key
The
PROG
key toggles between the OPERATOR menu and any other menu, remembering and
returning to previous positions in each menu. As you press the
PROG
key, the title of the menu
you are about to enter is displayed, i.e. OPERATOR or for example TRIPS. Releasing the key
clears the display and releases you into that menu.
WELCOME SCREEN
OPERATOR
PROG
The Menu System
M
E
SETPOINT (REMOTE)
to other parameters
to other menus/parameters
press immediately after
power-up to skip the
timeout
timeout
from
power-up
Figure 5-2 The Menu System showing Operation of the E, M and PROG Keys
The L/R Key
The
L/R
key (LOCAL/REMOTE) toggles between Remote and Local Control. In doing so, the
view of the SETPOINT parameter in the OPERATOR menu toggles between LOCAL
SETPOINT and REMOTE SETPOINT. The default is for the REMOTE SETPOINT parameter
to be displayed.
Note:
A different naming convention is applied in the OPERATOR menu for these parameters
when displayed as the first parameter entry:
•
REMOTE SETPOINT is displayed as SETPOINT (REMOTE)
•
LOCAL SETPOINT is displayed as SETPOINT (LOCAL)
•
COMMS SETPOINT is displayed as SETPOINT (COMMS)
Pressing the L/R key when in Remote mode takes you directly to the SETPOINT (LOCAL)
parameter with the Edit mode enabled. Press the PROG key to return to the previous display.
HEALTH
LOCAL
SEQ
REF
1
1
REMOTE SEQ
* KEY INACTIVE *
HEALTH
LOCAL
SEQ
REF
1
1
HEATSINK TEMP
* * * TRIPPED * * *
Содержание 605C
Страница 16: ...1 4 Getting Started 605C Frequency Inverter ...
Страница 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Страница 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Страница 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Страница 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Страница 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Страница 212: ...13 6 Application Notes 605C Frequency Inverter ...
Страница 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Страница 236: ......