Application Macros
15-1
6
605C Frequency Inverter
DIGITAL INPUT 7
VALUE [728]
–
FALSE
FALSE – [727] INVERT
–
DIGITAL INPUT 6
VALUE [726]
–
FALSE
FALSE – [725] INVERT
–
DIGITAL INPUT 8
VALUE [730]
–
FALSE
FALSE – [729] INVERT
–
VALUE FUNC 1
OUTPUT [133]
–
0.00 %
0.00 %
–
[130] INPUT A
–
0.00 %
–
[131] INPUT B
–
0.00 %
–
[132] INPUT C
–
A+B+C
–
[134] TYPE
–
VALUE FUNC 3
OUTPUT [143]
–
0.00 %
0.00 %
–
[140] INPUT A
–
0.00 %
–
[141] INPUT B
–
0.00 %
–
[142] INPUT C
–
BINARY DECODE
–
[144] TYPE
–
VALUE FUNC 5
OUTPUT [153]
–
0.00 %
0.00 %
– [150] INPUT A
–
0.00 %
–
[151] INPUT B
–
0.00 %
–
[152] INPUT C
–
SWITCH (A,B)
–
[154] TYPE
–
VALUE FUNC 9
OUTPUT [173]
–
0.00 %
0.00 %
– [170] INPUT A
–
0.00 %
–
[171] INPUT B
–
0.00 %
–
[172] INPUT C
–
SWITCH(A,B)
–
[174] TYPE
–
VALUE FUNC 2
OUTPUT [138]
–
0.00 %
0.00 %
– [135]
INPUT A
–
0.00 %
–
[136]
INPUT B
–
0.00 %
–
[137]
INPUT C
–
A+B+C
–
[139]
TYPE
–
VALUE FUNC 6
OUTPUT [158]
–
0.00 %
0.00 %
– [155]
INPUT A
–
0.00 %
–
[156]
INPUT B
–
0.00 %
–
[157]
INPUT C
–
SWITCH(A,B)
–
[159]
TYPE
–
ANALOG INPUT 1
VALUE [ 16] –
0.00 %
BREAK [ 18] – FALSE
100.00 % – [ 14] SCALE
–
0.00 % – [ 15] OFFSET
–
0..+10 V – [ 13] TYPE
–
FALSE – [ 12] BREAK ENABLE
–
0.00 % – [ 17] BREAK VALUE
–
ANALOG INPUT 2
VALUE [ 25] –
0.00 %
BREAK [ 27] – FALSE
100.00 % – [ 23] SCALE
–
0.00 % – [ 24] OFFSET
–
0..+10 V – [ 22] TYPE
–
FALSE – [ 21] BREAK ENABLE
–
0.00 % – [ 26] BREAK VALUE
–
ANALOG INPUT 3
VALUE [715] –
0.00 %
BREAK [717] –
FALSE
100.00 % – [713] SCALE
–
0.00 % – [714] OFFSET
–
0..20 mA – [712] TYPE
–
TRUE – [711] BREAK ENABLE
–
0.00 % – [716] BREAK VALUE
–
PRESET 1
OUTPUT 1 [356]
–
0.00 %
OUTPUT 2 [372]
–
0.00 %
INPUT 0
– [355] SELECT INPUT
–
0.00 %
–
[347] INPUT 0
–
0.00 %
–
[348] INPUT 1
–
0.00 %
–
[349] INPUT 2
–
0.00 %
–
[350] INPUT 3
–
0.00 %
–
[351] INPUT 4
–
0.00 %
–
[352] INPUT 5
–
0.00 %
–
[353] INPUT 6
–
0.00 %
–
[354] INPUT 7
–
RAISE/LOWER
OUTPUT [325]
–
0.00 %
FALSE
–
[327] RAISE INPUT
–
FALSE
–
[328] LOWER INPUT
–
10.0 s
–
[326] RAMP RATE
–
100.00 %
–
[330] MAX VALUE
–
0.00 %
–
[329] MIN VALUE
–
0.00 %
–
[331] RESET VALUE
–
FALSE
–
[332] RESET
–
ITEM 2
ITEM 3
(8)
(20)
(9)
(26)
(12)
(13)
(14)
(15)
(16)
(19)
(17)
(32)
(23)
(18)
(22)
(10)
(11)
(30)
INPUT C of VALUE FUNC 5 represents the
584S parameter AUTO SETPOINT select
INPUT C of VALUE FUNC 9 represents the
584S parameter MANUAL SETPOINT select
Macro 99: 584S Compatible Application
Содержание 605C
Страница 16: ...1 4 Getting Started 605C Frequency Inverter ...
Страница 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Страница 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Страница 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Страница 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Страница 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Страница 212: ...13 6 Application Notes 605C Frequency Inverter ...
Страница 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Страница 236: ......