6-70
Programming Your Application
605C Frequency Inverter
TRIPS STATUS
The Inverter supports advanced and flexible
trip logic to support monitoring of the
Inverter itself, the motor and the load. This
function block provides a view into the
current trip condition(s) and allows some
trips to be disabled.
MMI Menu Map
1
SETUP PARAMETERS
2
FUNCTION BLOCKS
3
TRIPS
4
TRIPS STATUS
DISABLED TRIPS
DISABLED TRIPS+
INVERT THERMIST
ACTIVE TRIPS
ACTIVE TRIPS+
TRIP WARNINGS
TRIP W
FIRST TRIP
TRIPS STATUS
ACTIVE TRIPS
[ 4]
–
0000
ACTIVE TRIPS+ [740]
–
0000
WARNINGS
[ 5]
–
0000
W [741]
–
0000
FIRST TRIP
[ 6]
–
NO TRIP
0600 – [231] DISABLED TRIPS
–
0000 – [742] DISABLED TRIPS+
–
FALSE – [760] INVERT THERMIST
–
Parameter Descriptions
DISABLED TRIPS and DISABLED TRIPS+
Range: 0000 to FFFF
Indicates which trips have been disabled. Not all trips may be disabled, the DISABLED TRIPS
mask is ignored for trips that cannot be disabled. See below for which trips may be disabled and
how this parameter is formed.
INVERT THERMIST
Range: FALSE / TRUE
Inverts the thermistor input.
ACTIVE TRIPS and ACTIVE TRIPS+
Range: 0000 to FFFF
Indicates which trips are currently active. These parameters are a coded representation of the
trip status. See below for a description of how this parameter is formed.
WARNINGS and W
Range: 0000 to FFFF
Indicates which conditions are likely to cause a trip. These parameters are a coded representation
of the warning status. See below for a description of how this parameter is formed.
FIRST TRIP
Range: Enumerated - see below
From when a trip occurs until that trip is reset, this parameter indicates the trip source. When
several trips have occurred, this parameter indicates the first one that was detected.
Enumerated Value
:
First Trip
0 : NO TRIP
1 : LINK OVERVOLTS
2 : LINK UNDERVOLT
3 : OVERCURRENT
4 : HEATSINK TEMP
5 : EXTERNAL TRIP
6 : INPUT 1 BREAK
7 : INPUT 2 BREAK
8 : MOTOR STALLED
9 : I*T TRIP
10 : BRAKE RESISTOR
11 : BRAKE SWITCH
12 : OP STATION
13 : LOST COMMS
14 :
15 :
16 :
17 : MOTOR TEMP
18 : CURRENT LIMIT
19 : SHORT CIRCUIT
20 : 24V FAILURE
21 : LOW SPEED I
22 : PHASE FAIL
or
MMI Menu Map
1
TRIPS STATUS
DISABLED TRIPS
DISABLED TRIPS+
INVERT THERMIST
ACTIVE TRIPS
ACTIVE TRIPS+
TRIP WARNINGS
TRIP W
FIRST TRIP
Содержание 605C
Страница 16: ...1 4 Getting Started 605C Frequency Inverter ...
Страница 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Страница 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Страница 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Страница 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Страница 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Страница 212: ...13 6 Application Notes 605C Frequency Inverter ...
Страница 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Страница 236: ......