4-2
Operating the Inverter
605C Frequency Inverter
Control Philosophy
There are four ways to control the Inverter using Remote and Local control:
Start/Stop and Speed Control
There are two forms of control in operation at any time:
Start/Stop
and
Speed Control
.
Each can
be individually selected to be under either Local or Remote Control.
•
Local or Remote Start/Stop
decides how you will start and stop the Inverter.
•
Local or Remote Speed Control
determines how you will control the motor speed.
In each case, Local and Remote control are offered by using the following:
Local:
The
Operator Station
Remote:
Analog and digital inputs and outputs, RS232 Port or the Technology Option
Thus the Inverter can operate in one of four combinations of local and remote modes:
analog
and digital
inputs and
outputs
PC running
ConfigEd Lite
or other suitable
software
Technology
REMOTE CONTROL
605C inverter
using
605C inverter
using
605C inverter
using
LOCAL CONTROL
605C inverter
using
Option
to fieldbus
and
Comms link
Operator
Station
DEFAULT
Figure 4-1 Remote and Local Control Modes
REMOTE START/STOP
REMOTE
LOCAL START/STOP
LOCAL
REMOTE START/STOP
LOCAL
LOCAL START/STOP
REMOTE
SPEED CONTROL
SPEED CONTROL
SPEED CONTROL
SPEED CONTROL
DEFAULT
SPEED SETPOINT
SPEED SETPOINT
SPEED SETPOINT
SPEED SETPOINT
Figure 4-2 The Four Combinations of Local and Remote Control
Содержание 605C
Страница 16: ...1 4 Getting Started 605C Frequency Inverter ...
Страница 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Страница 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Страница 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Страница 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Страница 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Страница 212: ...13 6 Application Notes 605C Frequency Inverter ...
Страница 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Страница 236: ......