Programming Your Application
6-25
605C Frequency Inverter
DIGITAL OUTPUT
The digital output block converts a logic TRUE or FALSE demand to a physical output signal.
Functional Description
The Inverter has three physical digital outputs (volt-free relay contacts). There is a DIGITAL
OUTPUT function block associated with each of these:
DIGITAL OUTPUT 1 is associated with terminals 21 & 22
DIGITAL OUTPUT 2 is associated with terminals 23 & 24
DIGITAL OUTPUT 3 is associated with terminals 25 & 26
INVERT reverses the output logic.
MMI Menu Map
1
SETUP PARAMETERS
2
FUNCTION BLOCKS
3
INPUTS & OUTPUTS
4
DIGITAL OUTPUT
5
DIGITAL OUTPUT 1
5
DIGITAL OUTPUT 2
5
DIGITAL OUTPUT 3
DOUT 3 VALUE
DOUT 3 INVERT
DIGITAL OUTPUT 2
FALSE – [ 55]
VALUE
–
FALSE
–
[ 54]
INVERT
–
DIGITAL OUTPUT 1
FALSE – [ 52]
VALUE
–
FALSE
–
[ 51]
INVERT
–
DIGITAL OUTPUT 3
FALSE – [737] VALUE
–
FALSE
–
[736] INVERT
–
Parameter Descriptions
VALUE
Range: FALSE / TRUE
The TRUE or FALSE output demand.
INVERT
Range: FALSE / TRUE
Controls the optional inversion of the VALUE output.
OUTPUT
INVERT
VALUE
Содержание 605C
Страница 16: ...1 4 Getting Started 605C Frequency Inverter ...
Страница 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Страница 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Страница 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Страница 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Страница 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Страница 212: ...13 6 Application Notes 605C Frequency Inverter ...
Страница 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Страница 236: ......