6-78
Programming Your Application
605C Frequency Inverter
Operation
Description
PULSE TRAIN
Creates a pulsed TRUE/FALSE output of programmable frequency.
INPUT A enables the pulse train when TRUE, disables when FALSE.
INPUT B sets the length of the
on
part of the pulse. INPUT C sets the length
of the
off
part of the pulse.
WINDOW
This function outputs TRUE when INPUT A is within a programmable
range, and FALSE otherwise.
INPUT B sets the threshold of the window to be monitored. INPUT C
defines the range of the window around the threshold. When the value of
INPUT A is inside the window, the window expands by 1.00% to avoid
flutter on output if noisy, i.e. if INPUT B = 5 and INPUT C = 4 then the
range is 3 to 7, expanded to 2.5 to 7.5 when the value if INPUT A is inside
the window.
If INPUT C is set to zero, the output will only be TRUE if INPUT A is
exactly equal to INPUT B (this is fulfilled in the default condition when
inputs A, B & C are all zero)
If INPUT C is set to a negative value, its absolute value defines the window
range, and the output is inverted.
input_a
output
ON time (input b)
OFF time (input_c)
input A
output
input B threshold
input C window width
input C +ve
input C -ve
Содержание 605C
Страница 16: ...1 4 Getting Started 605C Frequency Inverter ...
Страница 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Страница 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Страница 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Страница 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Страница 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Страница 212: ...13 6 Application Notes 605C Frequency Inverter ...
Страница 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Страница 236: ......