NAVIGAT 100
056373/D
NAVIGAT 100 Software Update
9-5
8. Place the PC/notebook with the SUSI software installed close aside
the gyrocompass housing.
In case a notebook is used, the notebook may be placed on top of
the gyrocompass housing.
9. Start the PC/notebook.
10. If SUSI is not running yet, start up the program now.
When prompted for the login PIN, either enter the service mode PIN
or leave the PIN empty.
5. To disconnect the jack of the
NAVIGAT 100 CDU cable, press
the socket latches with both
thumbs outwards to disengage the
jack from its socket.
6. Remove the jack from its socket.
7.
Place the door aside. If the door is
put next to the housing, the
grounding strap may be left con-
nected.
11. Plug in the type B connector of the
USB cable at the J31 USB service
port on the NAVIGAT 100 main-
board.
Note
The sequence of usage of the USB service ports (J31/J32) for software
update is free. The update procedures may equally be started with the
J31 service port, or with the J32 service port.