NAVIGAT 100
056373/D
Service Setup 610
7-27
Service Setup 610 – Parameters
GYROSPHERE DATA
Note
The gyrosphere current and temperature values are constantly moni-
tored by the system.
In case the gyrosphere current and/or temperature values get out of a
reasonable operating range corresponding alert messages will be issued
to indicate alert level and error type.
Displays gyrosphere current and voltage values.
GYRO CURRENT
Value:
0.225 A
The value given is an example.
Reasonable gyrosphere current values of a gyrosphere in
operable condition are usually below 0.250 A.
GYRO VOLTAGE
Value:
100.90 V
The value given is an example.
Reasonable gyrosphere voltage values of a gyrosphere in
operable condition lie usually between 100 to 102 V.